Loading ...
Loading ...
Loading ...
EN
45
Menu
www.bora.com
Start data export
Fig. 7.11 Menu item 9: Data export
Insert the formatted USB stick into the USB port.
Tap the slider
Data export is initiated.
The indicator for the first part of the export process
flashes.
INFO
If the data export is completed without errors, all
three segments will light up green.
INFO If an error occurs during data export (the
corresponding slider segment lights up red), the
data export is terminated. An error message
appears in the operating panel display (e.g.
E
1
2
3
;
see Troubleshooting chapter).
7.3.10 Menu item A:
Show the recirculation filter service
life (only in recirculation mode)
INFO The maximum service life of the recirculation
filter is defined by the filter type configured in the
system.
INFO The remaining filter service life is shown to the
exact hour in the multi-function display and also
on the slider by the colours green, orange and
red.
Indicator:
Remaining
service life
Colour Meaning
> 20 h Green filter change not yet required
5 – 20 h Orange filter change due soon
< 5 h Red Filter must be changed (very soon)
Tab. 7.2 Recirculation lter service life indicator
Update process
The update process has three stages. These three stages
are shown in the display by beige slider segments
(
). The currently active stage will flash. If a
stage in the process has been completed successfully,
the corresponding segment will stop flashing and will light
up green. The next stage in the process is started.
Fig. 7.10 Menu item 8: Software update process stages
INFO If the update is completed without errors, all three
segments will light up green. The system will then
be restarted automatically.
INFO The update has been completed successfully if
1
5
o
F
t
is shown in the display when the system
is restarted.
INFO If an error occurs during an update stage (the
corresponding slider segment lights up red), the
complete update process is terminated. An error
message appears in the operating panel display
(e.g.
E
1
2
3
; see Troubleshooting chapter).
7.3.9 Menu item 9:
Data export
INFO Data export makes error analysis easier.
INFO A USB stick with FAT32 formatting is needed
to save the exported data. This USB stick must
be inserted into the USB port on the cooktop
extractor.
INFO Data is exported in three stages. The stages of
the three processes can be seen in the operating
panel display as in the “software update” (see
Menu item 8).
Loading ...
Loading ...
Loading ...