ELECTRICAL SYSTEM INSTALLATION
Indoor Unit Electrical Connections
Using a Conduit for Indoor Unit Wiring / Cable
Installation
Use a liquidtight 3/4 inch elbow connector for flexible conduit to protect the communication / con-
nection (power) cable. The conduit can be positioned in the desired direction.
Before permanently positioning the refrigerant piping and drain hose at the back of the indoor unit,
install the conduit first.
1. Indoor unit includes a conduit bracket that can be found in the accessory kit. Assemble the
conduit and bracket with a grommet and washer (field-supplied or included with the elbow con-
nector) as shown.
2. Guide the power wiring / communication cable into the conduit / bracket assembly.
3. Attach the conduit / bracket assembly to the back of the indoor unit using the black Type D
screws found in the accessory kit.
Check local, state, and federal codes when choosing a conduit size.
)RUV\VWHPVZLWKZLULQJJUHDWHUWKDQIHHWVHHWKH³&RPPXQLFDWLRQ&RQQHFWLRQ3RZHU&DEOH6SHF-
LILFDWLRQVIURP2XWGRRU8QLWWR,QGRRU8QLW´LQWKH(OHFWULFDO6\VWHP,QVWDOODWLRQVHFWLRQIRULQIRUPDWLRQ
4. Close the piping holder, and, if all wiring and piping installation is complete, reassemble the
indoor unit properly onto the installation plate.
5. To protect the piping, condensate drain, and conduit from the elements, add a lineset cover
from the indoor access hole to the outdoor unit.
Figure 94: Liquidtight 3/4 Inch Elbow
Connector Attached to Flexible Conduit.
Figure 95: Indoor Unit Conduit / Bracket
Assembly.
Figure 96: Attaching the Conduit /
Bracket Assembly to the Back of the
Indoor Unit.
,IDFRQGXLWLVQRWXVHGVHHSDJHVLQWKH³5HIULJHUDQW3LSLQJ&RQQHFWLRQV´IRUUHIULJHUDQWSLSLQJFRQGHQ-
sate drain, power wiring / communication cable bundling information.