Installation and Operation Manual for Escape 1800
8
2 General Information on Escape 1800
DB03102
Escape 1800 - On pedestal - black door
DB03105
Escape 1800 - On black legs - black door
DB03111
Escape 1800 - On pedestal - brushed nickel door
DB03112
Escape 1800 On black legs - brushed nickel door
Note: a leg version cannot be converted to a pedestal version, nor a pedestal version
converted to a leg version.
2.1 Performance
(1)
Fuel type Dry cordwood
Recommended heating area
[*]
500 to 2,100 ft
2
(47 to 195 m
2
)
Firebox volume 2.4 ft
3
(0.068 m
3
)
Maximum burn time
[*]
8 h
Maximum heat output
(2)
(dry cordwood) 75,000 BTU/h (22.0 kW)
Overall heat output rate (min. to max.)
(2)(3)
14,800 BTU/h to 28,600 BTU/h
(4.34 kW to 8.38 kW)
Average overall efficiency
(3)
- Dry cordwood 69 % (HHV
(4)
) 74 % (LHV
(5)
)
Optimum efficiency
(2)(6)
77 %
Average particulate emissions rate
(7)
1.54 g/h (EPA / CSA B415.1-10)
(8)
Average CO
(9)
89.4 g/h
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss
factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the
manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a
power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn
time and maximum heat output.
(2)
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
.
Other performances are based on a fuel load prescribed by the standard. The specified loading density varies
between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19% and 25%.
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and Draft ASTM
WK47329-14
(9)
Carbon monoxide.
Loading ...
Loading ...
Loading ...