Installation and Operation Manual for Escape 1800
33
7.2.1 Clearances with ceiling (L) lowered to 77" (196 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH SINGLE WALL
PIPE CONNECTOR)
CANADA
USA
A
14 ½" (368 mm)
11" (279 mm)
B
19" (483 mm)
18" (457 mm)
C
10" (254 mm)
10" (254 mm)
K
48" (122 cm)
48" (122 cm)
L
77" (196 cm)
77" (196 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE
WALL PIPE CONNECTOR)
CANADA
USA
A
9" (229 mm)
9" (229 mm)
B
19" (483 mm)
19" (483 mm)
C
7" (178 mm)
7" (178 mm)
K
48" (122 cm)
48" (122 cm)
L
77" (196 cm)
77" (196 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
2
FROM PIPE
CONNECTOR WITH SINGLE WALL
PIPE CONNECTOR
CANADA
USA
D
18" (457 mm)
14 ½" (368 mm)
E
28 ½" (724 mm)
27 ½" (699 mm)
F
19 ¾" (502 mm)
19 ¾" (502 mm)
DISTANCES
2
FROM PIPE
CONNECTOR WITH DOUBLE WALL
PIPE CONNECTOR
CANADA
USA
D
12 ¼" (311 mm)
12 ¼" (311 mm)
E
28 ¼" (718 mm)
28 ¼" (718 mm)
F
16 ½" (419 mm)
16 ½" (419 mm)
Clearances with heat shield (AC02710) and ceiling lowered
Note that to reduce the clearances of an appliance using a single wall pipe connector, the
use of a heat shield certified with the single wall pipe connector to be used as close as 6"
from combustible materials must be used. Only in this case, the same clearances as a
certified double wall pipe connector can be used.
APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE
WALL PIPE CONNECTOR)
CANADA
USA
A
5" (127 mm)
5" (127 mm)
B
6" (152 mm)
6" (152 mm)
C
5" (127 mm)
5" (127 mm)
K
48" (122 cm)
48" (122 cm)
L
80" (203 cm)
80" (203 cm)
If the above clearances are met, then the
distances measured from the flue outlet will
be:
DISTANCES
2
FROM DOUBLE
WALL PIPE CONNECTOR
CANADA
USA
D
8 ¼" (210 mm)
8 ¼" (210 mm)
E
15 ¼" (387 mm)
15 ¼" (387 mm)
F
14 ½" (368 mm)
14 ½" (368 mm)
2
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance
with the appliance clearances above mentioned.