TEMPERATURE DIFFERENTIAL (variation “SWING”)
The THERMO mode on the transmitter operates with TEMPERATURE DIFFERENTIAL (also called variation “SWING”).
A smaller SWING increases the number of cycles so the room temperature is updated more often which consume more
battery power. A larger SWING decreases the number of cycles, so the tolerance of ROOM temperature is larger, but
can save some battery.
The factory default setting for the SWING is 2 which means a temperature variation of +/- 2°F (1°C) between SET
temperature and ROOM temperature, which determines when the system will be ON or OFF.
There are three SWING numbers for user’s choice: +/- 1°F (0.5°C), +/- 2°F (1°C) , and +/- 3°F (1.6°C). See Fig. 12.
Fig. 12
Fig. 13
SETTING THE SWING
1. To change the temperature SWING setting, press the “TIMER” and buttons (Fig. 13) at the same time to display
the current SWING setting (Fig. 12). The letter “S” (looks like Arabic number 5”) means you are currently in the SWING
setting,
2. Press the and buttons to change the SWING (1, 2 , 3).
3. To store the desired SWING number, press the OK button or wait for 15 seconds without any actions, then transmitter
will accept the setting and become programmed.