SYSTEM TESTS & CHECK LIST
MILLIVOLT VALVES
Please DO take following tests and make sure all functions are working fine:
1. Slide the slide switch button on the receiver to the ON (Fig. 8). The main gas fire flame should ON.
2. Slide the button to OFF. The main gas fire flame should extinguish and the pilot flame will remain ON.
3. Slide the button to REMOTE, and press the MODE button on the transmitter to change the system to ON. The main
gas fire flame should ON.
4. Press the MODE button on the transmitter to change the system to OFF. The main gas fire flame should extinguish
and the pilot flame will remain ON.
5. Press the MODE button on the transmitter to change the system to THERMO mode. Make the SET temperature on
the transmitter to a temperature of a least 2 ° F (1° C) above the ROOM temperature displayed on the LCD screen, the
system flame and main gas fire flame will be ON. Then make the SET temperature to at least 2°F (1°C) below the ROOM
temperature, the system flame and main gas fire flame will extinguish in seconds. It should continue to cycle ON and OFF
thermostatically. The temperature differential between ROOM and SET temperatures differ at least 2°F (1°C) to start the
THERMO cycling. (The 2°F differential is the factory setting, can NOT be changed.)
ELECTRONIC IGNITION SYSTEMS
Please DO take following tests and make sure all functions are working fine:
1. Slide the slide switch button on the receiver to the ON (Fig. 8). The spark igniting electrode should begin sparking to
ignite the pilot. Once the pilot flame is lit, the main gas valve should open and the main gas fire flame should be ON.
2. Slide the button to OFF. The main gas fire flame and pilot fire flame should extinguish together.
3. Slide the button to REMOTE, and then press the MODE button on the transmitter to change the system to ON. The
spark igniting electrode should begin sparking to ignite the pilot. Once the pilot flame is lit, the main gas valve should open
and the main gas fire flame should be ON.
4. Press the MODE button to OFF. The main gas fire flame and pilot fire flame should extinguish together.
5. Press the MODE button on the transmitter to change the system to THERMO. Make the SET temperature on the
transmitter to a temperature of a least 2°F (1°C) above the ROOM temperature displayed on the LCD screen, the system
flame and main gas fire flame will be ON. Then make the SET temperature to at least 2 ° F (1 ° C) below the ROOM
temperature, the system flame and main gas fire flame will extinguish in seconds. It should continue to cycle ON and OFF
thermostatically. The temperature differential between ROOM and SET temperatures differ at least 2°F (1°C) to start the
THERMO cycling. (The 2°F differential is the factory setting, can NOT be changed.)