Hydro Smart HS120CON-LP 120K BTU Condensing Gas LP Microboiler

Installation Manual and Owner’s Guide - Page 36

For HS120CON-LP. Also, The document are for others Hydro Smart models: HS120CON-NG

PDF File Manual, 60 pages, Read Online | Download pdf file

HS120CON-LP photo
Loading ...
Loading ...
Loading ...
Installation Manual
Page
36
-One zone system-
-Multi zone by Actuator/Telestat system-
Optional Items
Item #6: HSPS120LT (One zone panel) - This Master One
Zone Panel (Low Temp-Max. 155° F) is utilized when 1
thermostat zone is required in the system. The panel extracts
the heated uid from the boiler and processes the heated
uid to the emitter circuit. Boiler and emitter circuits have
hydraulic separation for independent ow adjustments.
Item #7: HSPS120MTL (Master Pro Integrator Panel -
Zoning by Actuator) - This Master Zoning by Actuator
Panel (Low Temp-Max. 155° F) utilizes primary/secondary
plumbing just like the one zone panels. This panel would be
a great choice when you have multiple zones with emitters
that have the same water delivery temperatures, less than
1800 sqft. total and can bring all the loops to 1 central
manifold. Note: This options requires 1 actuator( Item
#8) for each loop/run of your system (6 Max.) Each zone
must have min. of 600 sqft.
Item #8: Thermo-Electric Zoning Actuator - Actuators
open and close when thermostats call for heat and can
be grouped together for thermostatically controlled zones
with more than 1 loop (there should always be a minimum
of 2 loops per zone). These actuators have a control knob
for manual opening, valve opening/closing indicator and a
device for returning to automatic operation from the manual
position.
Hydronic Manifold - Always use a hydronic manifold
not a potable water manifold for your radiant heating
system. Hydronic manifolds have ow control valves
and site ow gauges. Ideal ow rate of .5 to .8
GPM per loop/run. (Call 1-763-331-3066 for order
assistance.)
6
6
7
7
8
8