Loading ...
Loading ...
Loading ...
6 7
WIRING TERMINAL
Wire specifications
18-24 gauge thermostat wire
Installation notes
Ensure power at the HVAC
equipment is off.
Loosen screw terminals,
insert stripped wire and
re-tighten.
Push the excess wire
back into the opening and
plug the wall opening to
prevent drafts.
INSTALLATION
RC24 VAC supply cooling*
R24 VAC supply heating*
WFirst stage heat (conventional) / First stage auxiliary (heat pump)
YFirst stage cooling (conventional) / First stage compressor (heat pump)
G – Fan
CCommon
S1 & S2 – Outdoor temperature sensor (optional)
O/BReversing valve
L – System fault indicator
W2Second stage heat (conventional) / Second stage auxiliary (heat pump)
Y2Second stage cooling (conventional) / Second stage compressor (heat pump)
* Jumper between RC & R is used in single transformer systems (see wiring diagrams).
C
G
Y
W
R
L
S1
S2
O/B
W2
Y2
RC
WIRING – SINGLE TRANSFORMER (USE
JUMPER WIRE) FOR HEAT/COOL SYSTEM
INSTALLATION
1st HEATING
1st COOLING
FAN
2nd HEATING
2nd COOLING
OUTDOOR TEMP
SENSOR
NOT USED
NOT USED
JUMPER
TRANSFORMER
C
G
Y
W
R
L
S1
S2
O/B
W2
Y2
RC
WIRING – TWO TRANSFORMERS (REMOVE
JUMPER WIRE) FOR HEAT/COOL SYSTEM
1st HEATING
1st COOLING
FAN
2nd HEATING
2nd COOLING
OUTDOOR TEMP
SENSOR
NOT USED
NOT USED
HEATING
TRANSFORMER
COOLING
TRANSFORMER
C
G
Y
W
R
L
S1
S2
O/B
W2
Y2
RC
Loading ...