Napoleon B42NTR Ascent 42

User Manual - Page 51

For B42NTR. Also, The document are for others Napoleon models: B42NTRE, B42PTR, B42PTRE

PDF File Manual, 148 pages, Read Online | Download pdf file

B42NTR photo
Loading ...
Loading ...
Loading ...
EN
W415-2367 / B / 12.09.20
51
finishing
10.4 minimum mantel clearances
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed. These same requirements apply to any combustibles protruding on either side of the appliance.
TOP OF
APPLIANCE
2"
50.8mm
4"
101.6mm
6"
152.4mm
8"
203.2mm MANTEL
4"
101.6mm
2"
50.8mm
6"
152.4mm
8"
203.2mm
34 5/8”
[88cm]
MANTEL
HEIGHT
0
2" (50.8mm)
2 4 6 8 10 12
MANTEL DEPTH (INCHES)
4" (101.6mm)
6" (152.4mm)
10" (254mm)
12" (30.5cm)
8" (203.2mm)
!
WARNING
45.4
Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructions
may cause a fi re or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
When using paint or lacquer to fi nish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.