2.1 Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Model LEGEND III (DB03073)
Combustion Technology Non-catalytic
Fuel Type Dry Cordwood
Recommended heating area (sq. ft.
.
)
1
900 to 2,300 ft
2
(83.6 to 213.7 m
2
)
Fi
rebox volume
3
.3 ft
3
(0.093 m
3
)
EPA loading volume 2.67 pi
3
(0.056 m
3
)
Maximum burn time
1
10 hours
Maximum heat output (dry cordwood)
2
90,000 BTU/h (26.4 kW)
Overall heat output rate (min. to max.)
2 3
15,841 BTU/h to 57,041 BTU/h
(4.64 kW to 16.72 kW)
Average overall efficiency
3
Dry cordwood
71.1 % (HHV)
4
76.6 % (LHV)
5
Optimum efficiency
6
78 %
Average particulate emissions rate
7
0.95 g/h (EPA / CSA B415.1-10)
8
Average CO
9
61.3 g/h
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is dened by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
. Other performances are based on
a fuel load prescribed by the standard. The specied loading density varies between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19%
and 25%.
3
As measured per CSA B415.1-10 stack loss method.
4
Higher Heating Value of the fuel.
5
Lower Heating Value of the fuel.
6
Optimum overall efciency at a specic burn rate (LHV).
7
This appliance is ofcially tested and certied by an independent agency.
8
Tested and certied in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14
9
Carbon monoxide.