Installation and Operation Manual - Legend III
ENGLISH
8.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA Canada USA
A
14 ½" (368 mm) 14 ½" (368 mm)
A
8" (203 mm) 8" (203 mm)
B
15" (381 mm) 15" (381mm)
B
14" (356 mm) 14" (356 mm)
C 12" (305 mm) 12" (305 mm) C 10" (254 mm) 10" (254 mm)
L 70" (1778 mm) 70" (1778 mm) L 70" (1778 mm) 70" (1778 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
15
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
15
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
D 18" (457 mm) 18" (457 mm) D
11 ½" (292 mm) 11 ½" (292 mm)
E 23 ¾" (603 mm) 23 ¾" (603 mm) E 22 ¾" (578 mm) 22 ¾" (578 mm)
F 21 ¾" (552 mm) 21 ¾" (552 mm) F 19 ¾" (502 mm) 19 ¾" (502 mm)
8.1.3 With Heat Shield AC02762 and Lowered Ceiling
16
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
DISTANCES FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
A 5" (127 mm) 5" (127 mm)
D
8 ½" (216 mm) 8 ½" (216 mm)
B 3" (76 mm) 3" (76 mm)
E
11 ¾" (298 mm) 11 ¾" (298 mm)
C 3 ½" (89 mm) 3 ½" (89 mm)
F
13 ¼" (337 mm) 13 ¼" (337 mm)
L
73" (1854 mm) 73" (1854 mm)
L
73" (1854 mm) 73" (1854 mm)
15
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
16
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certied with the single wall pipe connector
to be used as close as 6" (153 mm) from combustible materials must be used. Only in this case, the same clearances as a certied double wall
pipe connector can be used.