14
ASSEMBLY
Refer to “TOOLS & WORKSPACE” from “DISASSEMBLY” on Page 12
Installing the FRONT GRILLE:
1. Gently set the bottom of the FRONT GRILLE in place on the lower front of the
purifier and swing the top of the FRONT GRILLE into place, being careful not to
damage the IONIZATION NEEDLE at the top center of the front of the purifier.
2. Insert the two FRONT GRILLE SCREWS one at a time until they are in place, but
not tight. After both FRONT GRILLE SCREWS are in place, tighten them carefully.
Installing the PCO CELL:
1. Position the PCO CELL inside the purifier so that the two tabs are on the bottom
of the PCO CELL. Ensure the holes in the two tabs fit over the two screw posts.
Screw the PCO CELL RETAINING NUTS onto the screw posts until they are snug.
2. Align the PCO CELL CONNECTOR to the PCO CELL CONNECTOR outlet and insert
gently until the tabs at the top and bottom of the PCO CELL CONNECTOR snap
into place, holding it in the PCO CELL CONNECTOR outlet.
Installing the PURIFICATION PLATE:
1. Holding the PURIFICATION PLATE by the ceramic, slowly insert it into the
PURIFICATION PLATE slot, ensuring that the PURIFICATION PLATE is sliding into the
grooves on either side.
NOTE: About halfway in, the PURIFICATION PLATE connectors are parted.
Continue sliding the PURIFICATION PLATE into the PURIFICATION PLATE slot until
there is approximately one inch of the PURIFICATION PLATE remaining outside
of the PURIFICATION PLATE slot and significant resistance is met. Be careful not
to force the PURIFICATION PLATE further into the PURIFICATION PLATE slot as this
could seriously damage your purifier.