8
Installation
Space requirements for installation
When moving the ice maker, check whether the prepared
opening dimensions, electric power, and piping position are
correct.
Refer to the installation specifications and drawings shown on
pages 10 and 11.
Figures 4, 5, 6 and 7 show the dimensions of the ice makers.
Model BIM68OSGDR is a gravity drain pipe model that
requires a drain pipe to run from the exhaust hole at the back
of the product to an appropriate drain.
Model BIM68OSPUMP has an internal pump that can raise
excess water to a drainage point such as a neighboring sink.
Refer to the specifications shown on pages 10 and 11.
Important Information:
Be aware that if the ice maker is
installed in
a corner, you must leave enough space so that
the opening of the door is not obstructed. Adjust the legs at
the bottom of the ice maker to be sure it is level.
When moving the ice maker using a hand truck or dolly, place
the dolly at the side of the unit and shut or fix the door tightly
to avoid possible opening during transport. Cover the ice
maker with a blanket or other suitable material to avoid
possible damage when moving the product.
Requirements for power supply
120VAC, 60Hz, 15-amp circuit breaker and electric power are
required. A separate circuit is required for grounding.
The power cord of the product should be inserted into a
suitable 3-prong grounding-type socket.
Important Information:
A Ground Fault Circuit Interrupter
(GFCI) is not recommended because it could cause the
operation of the product to stop.
Important Information: The provisions of the National Electric
Code as well as any local laws and instructions should be
observed when installing the product
.
Warning!
Do not use extension cords or 2-prong adapters. The product must be grounded.