Westinghouse GGR475WLPG 60cm LPG Gas Built-In Oven

User Manual - Page 24

For GGR475WLPG.

PDF File Manual, 32 pages, Download pdf file

Loading ...
Loading ...
Loading ...
24
INSTALLATION
GAS CONNECTION
Before commencing installation, check to ensure the type
of gas to which the appliance is intended to be connected
matches the gas type given on the appliance data plate.
Check the data plate (located behind the oven door) to
determine gas type. A gas type label is located on the
back panel near the gas inlet.
A 1700mm long flexible hose is supplied in the pack for
installation purposes.
CONNECTING FLEXIBLE HOSE
Place a spanner on the flats provided on the gas inlet
to brace the inlet against the action of wrenching when
connecting the hose to the appliance gas inlet. Failure to
do so may damage the appliance.
An approved thread sealing tape or compound is
required for the connection between the hose and the
appliance gas inlet.
APPLIANCES FOR OPERATION ON N.G. & S.N.G.
For N.G. and S.N.G appliances the supplied N.G. regulator
must be fitted. For L.P.G appliances (Propane or
Universal LP) the test point fitting supplied must be fitted.
NOTE: The inlet of the regulator or test point fitting should
be fitted to the consumer piping first. The arrow on the
regulator or test point fitting indicates the direction of gas
flow. Then connect the hose to the outlet of the regulator
or test point fitting using the swivel connection on the hose
and fibre washer supplied.
Ensure the regulator or test point fitting is in
a position that is accessible with the appliance
installed and which will allow the appliance to
be withdrawn without disconnecting the hose.
GAS INSTALLATION INFORMATION
Gas flow
to appliance
Internal flange
N.G. Regulator
Important: flat fibre washer
must be installed
Loading ...
Loading ...
Loading ...