26
HOW TO MAINTAIN THE STRENGTH SYSTEM
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the strength system is used.
Replace any worn parts immediately.
To clean the strength system, use a damp cloth and
a small amount of mild detergent. IMPORTANT: To
avoid damage to the console, keep liquids away
from the console and keep the console out of
direct sunlight.
HOW TO TROUBLESHOOT THE CONSOLE
If the console does not turn on, make sure that the
power adapter is fully plugged in.
If the console does not display your heart rate
when you use the chest heart rate monitor, see
TROUBLESHOOTING on page 18.
If a replacement power adapter is needed, call the
telephone number on the cover of this manual.
IMPORTANT: To avoid damaging the console, use
only a manufacturer-supplied regulated power
adapter.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed switch, first unplug the power
adapter, and then follow the steps below.
See assembly step 8 on page 14. Remove the
Front and Rear Bottom Covers (67, 109) from the
bottom of the strength system.
See EXPLODED DRAWING B on page 34. Identify
the Rear Shroud (59). Remove the four #8 x 3/4"
Screws (86) and the Rear Shroud from the strength
system.
Next, locate the Reed Switch (25). Slightly loosen the
indicated screw (A).
Then, rotate the Resistance Disc (6) until a Magnet
(119) is aligned with the Reed Switch (25). Slide the
Reed Switch slightly toward or away from the Magnet.
Then, retighten the screw (A).
Plug in the power adapter and rotate the Resistance
Disc (6) for a moment. Repeat these actions until the
console displays correct feedback.
When the reed switch is correctly adjusted, reattach
the parts that you removed. Then, plug in the power
adapter.
25
6
A
119
MAINTENANCE AND TROUBLESHOOTING
Loading ...
Loading ...