Running at 400V3N~ (models connected
according to DIAGRAM "A"): use a pentapolar
cable type H05RR-F/H05RN-F (cable measuring
5 x 2.5 mm
2
).
Running at 230V3~ (models connected accord-
ing to DIAGRAM "C" but commutated by the
installer according to DIAGRAM "B"): use a
tetrapolar cable type H05RR-F/H05RN-F (cable
measuring 4 x 4 mm
2
).
Running at 230V1N~ (models connected
according to DIAGRAM "C"): up to 2.9 kW use
a tripolar cable type H05RR-F/H05RN-F (cable
measuring 3 x 1.5 mm
2
); between 2.9 kW and
5.4 kW use a tripolar cable type H05RR-
F/H05RN-F (cable measuring 3 x 2.5 mm
2
).
The end to be connected to the appliance must
have the earth wire (yellow-green) at least
20 mm longer.
Electronic power cable
section
According to the type of power supply, use a cable
that conforms to the following table.