Loading ...
Loading ...
Loading ...
51
Wireless
Multi-Location Installation - Caséta Wireless In-Wall Neutral Switch with Pico Remote Controls
8
Connect the new Caséta Wireless neutral switch
9
Mount the Caséta Wireless neutral switch
10
Attach the wallplate
‘snap’
Wallplate
Adapter
Wallplate
Tagged wire
Location 1
Location 1
Location 1
6
Tag and disconnect wires from the existing switch
7
Remove side sections (if necessary)
Different
Color Screw
Ground
(Green / Bare Copper)
Place tag - to identify wire on
different color screw
Location 1
Multi-Location Installation - Caséta Wireless In-Wall Neutral Switch with Pico Remote Controls
Do not remove outside side sections
on switches at the end of gang.
Each switch has inside
side sections removed.
Switch in the middle has
all side sections removed.
When installing more than one Caséta Wireless switch in the same wallbox,
it is necessary to remove inner side sections prior to wiring. See image and
chart below for more information.
Important note:
Removing side sections reduces the switch’s maximum wattage
rating. See the chart below for maximum wattage information.
Black
Blue
Red
Ground
(Green Wire)
Neutral
connection
required
1
Neutral required.
2
The maximum lamp wattage is determined by the efficiency of the transformer, with
70% – 85% as typical. For actual transformer efficiency, contact either the fixture or
transformer manufacturer. The total VA rating of the transformer(s) shall not exceed the VA
rating of the in-wall switch.
3
The in-wall switch is ULR Listed for use with all magnetic and electronic fluorescent ballasts.
B
B B
C
B
A
PD-6ANS (120 V~)
1
LED 6 A 6 A 5 A
Halogen / incandescent 720 W 720 W 600 W
Electronic Low-Voltage 720 VA 720 VA 600 VA
Magnetic Low-Voltage
2
720 VA 720 VA 600 VA
Fluorescent
3
6 A 6 A 5 A
General Purpose Fan 3.6 A 3.6 A 3.6 A
A
B C
White
Neutral
connection
required
Loading ...
Loading ...
Loading ...