PREPARING THE INSTALLATION LOCATION
INSTALLATION INSTRUCTIONS
IMPORTANT INSTALLATION
INFORMATION
All electric cooktops run off a single phase,
three-wire or four-wire cable, 240/208 volt, 60
hertz, AC-only electrical supply with ground.
Minimum distance between cooktop and
overhead cabinetry is 30″ (762 mm).
Make sure the cabinets and wall coverings
around the cooktop can withstand the
temperatures (up to 93°C [200°F]) generated
by the cooktop.
** Do not obstruct these areas!
36 inch Radiant Cooktop
4" X 8" (102 mm x 203
mm) opening to route
armored cable if panel is
present.
30″ Min.
(762 mm)
LCE3610SB Radiant Cooktop
Unit A B C D E
F G
H
I J
K L
Min Min Max Min
Inch 36-11/16 21-15/16 3-3/4 33-27/32 19-25/32 34-9/16 20-3/8 13/16 13 5-23/32 2-1/2 24
mm 932 557 95 860 502 878 517 20 330 145 64 610
All dimensions are stated in inches and millimeters (mm).
Allow 2″ (50 mm) space below the armored cable opening to clear the electric cable and allow
space for installation of the junction box on the wall at the back of the cooktop.