Loading ...
Loading ...
Loading ...
25
Performance Data Sheet
28
PERFORMANCE DATA SHEET
Water Filtration System
Model P8WB2L/P8RFWB2L Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53 and 401 for the reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI Standards 42, 53, and 401
.
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.75 gpm (2.84 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 6F to 71.6°F (20°C to 22°C). Rated service
capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental contaminants are those
compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/
perception of drinking water quality.
It is important that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised. Property
damage can occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter P8RFWB2L, part #EDR1RXD1/EDR1RXD1B.
2015 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices are
subject to change without notice.
The filter monitor system measures the amount of water that passes through the
filter and alerts you when it is time to replace the filter. Refer to the “Using the
Controls” or “Water Filtration System” section (in the User Instructions or User
Guide) to learn how to check the water filter status.
After changing the water filter, flush the water system. See “Water and Ice
Dispensers” or “Water Dispenser” in the User Instructions or User Guide.
These contaminants are not necessarily in your water supply. While testing was
performed under standard laboratory conditions, actual performance may
vary.
The product is for cold water use only.
The water system must be installed in compliance with state and local laws and
regulations.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certified for
cyst reduction may be used on disinfected waters that may contain filterable
cysts.
EPA Est. No. 082047-TWN-001
Refer to the “Warranty” section (in the User Instructions or User Guide) for the
Manufacturer’s limited warranty, name and telephone number.
Application Guidelines/Water Supply Parameters
System tested and certified by NSF International against NSF/ANSI
Standard 42, Standard 53, and Standard 401 for the reduction of
contaminants specified on the Performance Data Sheet.
Substance Reduction Aesthetic Effects Influent Challenge Concentration Maximum Permissable
Product Water Concentration
Average% Reduction
Chlorine Taste/Odor
Particulate Class I
*
2.0 mg/L ± 10%
At least 10,000 particles/mL
50% reduction
85% reduction
97.0%
>99.9%
C
ontaminant Reduction Influent Challenge Concentration Maximum Permissable
Product Water Concentration
Average% Reduction
Lead: @ pH 6.5 / @ pH 8.5 0.15 mg/L± 10% 0.010 mg/L >99.3% / 98.6%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 93.8%
p-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.8%
Carbofuran 0.08 mg/L ± 10% 0.040 mg/L 81.9%
Toxaphene 0.015 ± 10% 0.003 mg/L >95%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 87.0%
Asbestos 10
7
to 10
8
fibers/L
††
99% >99%
Live Cysts
50,000/L min. 99.95% >99.99%
Turbidity 11 NTU ± 10% 0.5 NTU 96.9%
Lindane 0.002 ± 10% 0.0002 mg/L >99.2%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.6%
o-Dichlorobenzene 1.8 mg/L ± 10% 0.60 mg/L 92.3%
Ethylbenzene 2.1 mg/L ± 10% 0.70 mg/L 86.9%
1,2,4-Trichlorobenzene 0.210 mg/L ± 10% 0.07 mg/L >99.8%
2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 88.5%
Styrene 2.0 mg/L ± 10% 0.1 mg/L 99.6%
Toluene 3.0 mg/L ± 10% 1.0 mg/L 93.5%
Endrin 0.006 mg/L ± 10% 0.002 mg/L 81.7%
Atenolol 200 ± 20% 30 ng/L 95.7%
Trimethoprim 140 ± 20% 20 ng/L 96.1%
Linuron 140 ± 20% 20 ng/L 96.3%
Estrone 140 ± 20% 20 ng/L 95.3%
Nonylphenol 1400 ± 20% 200 ng/L 95.5%
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.75 gpm (2.84 L/min.) @ 60 psi
*
††
Class I particle size: >0.5 to <1 um
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.
Loading ...
Loading ...
Loading ...