4 Choosing a location Kelvinator Air Conditioning
Choosing a location to mount unit
Indoor unit
Do not install the unit near any heat source, ammable gas or
steam.
Choose a location where the air circulation is good, and where
there are no obsticles blocking the air ow.
Select a place that will be convenient to run a drain to suitable
location outside.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the restrictions on installation sp
ed in the indoor
unit installation drawings are met.
Select a location which is
enough for installation so that
the device is not subjected to vibrations.
The device should be installed at a distance of at least 1m
from all other electrical devices and installations, e.g. TV,
radio,computer, etc.
Avoid installing in direct sunlight, if it's unavoidable consider
installing something to protect from direct sunlight.
reas
Your air conditioner is designed to condition the air for a certain
range of room size, please ensure the selection of your air
conditioner complies with the Kelvinator selection tool available
from www.kelvinator.com.au
This product uses mildly
ammable R32 refrigerant. Certain levels
of refrigerant require minimum room sizes. Please ensure that these
minimum room sizes are adhered to for standard installations (up
to 5m pipe length). If larger refrigerant charges than standard are
used then please consult AS/NZS 60335.2.40 to determine the safe
minimu
oor area for the installation.
Outdoor unit
If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
Do not install outdoor unit in a location where the air outlet will
be directed on plants or animals as it may harm them.
Make sure that there is suf
nt space as spe ed in the
installation drawings.
Do not place any obstacles which may cause a short circuit of
the discharged air.
Select a location which avoids causing a nuisance to
neighbours from noise and air emissions from device.
Select a location which is suf
ntly well ventilated.
Never cover the air inlets and outlets.
The location must be suf
e r installation and the
prevention of vibrations.
There must be no risk presented by combustible gas or gas
escaping as a result of corrosion.
Avoid a location where there is a high salt content.
Avoid a location which is heavily exposed to dust.
Avoid a location to which the general public have access.
Model Charge of R32 (g)
Minimum r area (m
2
)
KSV25CRH
KSV25HRH
KSD25HRH
KSV35CRH
KSV35HRH
KSD35HRH
KSV71CRH
KSV71HRH
KSD71HRH
KSV50HRH
KSD50HRH
KSV90HRH
KSD90HRH
830
N/A
900 N/A
2700
6.95
1450 2.00
1600 2.44