Troubleshooting
Tel: 1-800-26 - (1-800-263-2629)
PROBLEM POSSIBLE CAUSE SOLUTION
Dehumidi er does
not start
• The dehumidi er is unplugged
The fuse is blown/circuit
breaker is tripped
• Dehumidi er has reached its
preset level or bucket is full
Bucket is not in the proper
position
• Power failure
Make sure the plug is pushed completely into the outlet
Check the house fuse/circuit breaker box and replace
the fuse or reset the breaker
The unit turns off automatically when either condition oc-
curs. Change to a lower setting or empty the bucket and
replace properly
The bucket must be in place and securely seated for the
unit to operate.
There is a protective time delay (up to 3 minutes) to
prevent tripping of the compressor overload. For this
reason, the unit may not start normally for 3 minutes
after it is turned back on.
Dehumidi er does
not dry the air as it
should
Did not allow enough time to
remove the moisture
• Air ow is restricted
• Dirty lter
The humidity control may not
be set low enough
Doors and windows may not
be closed tightly
Clothes dryer may be blowing
moisture-laden air into the
room
Room temperature is too low
• When rst installed, allow at least 24 hours to maintain
the desired dryness
Make sure there are no curtains, blinds or furniture
blocking the front or back of the dehumidi er. See the
“Location” section.
See the “Air lter” section
For drier air, press the down button and set to a lower
percent value (%)
Check that all doors, windows and other openings are
securely closed
Install the dehumidi er away from the dryer. The dryer
should be vented to the outside.
Moisture removal is best at higher room temperatures.
Lower room temperatures will reduce the moisture
removal rate. Modes are designed to be operated at
temperatures above 5°C (41°F)
Dehumidi er runs
too much but does
not collect water
Need to reset controller Set to lowest humidity setting. Allow bucket to ll and
then empty bucket. Adjust controller to desired % RH.
Dehumidifer runs
too much collects
water
Area to be dehumidifed is too
large
Doors and windows are open
The capacity of your dehumidi er may not be adequate
Close all doors and windows
Frost appears on
the coils
Unit has been recently turned
on, or room temperature is too
cold
This is normal. Frost will usually disappear within 60
minutes. See the “Defrost” section
Controls cannot be
set
The compressor will turn off
and the fan will automatically
continue to run for approx. 3
minutes at a xed setting
This is normal. Wait approximately 3 minutes and set
the fan as desired.
Fan noise Air is moving through the
dehumidi er
This is normal
Water on oor Hose connection may be
loose
Bucket used to collect water,
but the hose is attached
Check the hose connection. See “Continuous Drain”
section
Disconnect the hose if using the bucket to collect water,
see “Continuous Drain” section.
11