TABLE N°1
Adaption to various types of gas
Burners
Gas type
Pressure (kPa)
Injector
(mm)
Mj/hr
Small
Natural
1.00
0.90
3.60
Small
LPG
2.75
0.54
3.60
Medium
Natural
1.00
1.18
6.30
Medium
LPG
2.75
0.70
6.30
Large
Natural
1.00
1.55
10.80
Large
LPG
2.75
0.92
10.80
Wok
Natural
1.00
1.80
14.40
Wok
LPG
2.75
1.08
14.40
Wok 2way
Natural
1.00
Ex.1.80
int.0.80
18.00
Wok 2way
LPG
2.75
Ex. 1.08
int. 0.50
18.00
Oven
Natural
1.00
1.95
17.0
Oven
LPG
2.75
1.10
17.0
Test the operation of the cooker before leaving
Note: These burners have no aeration adjustment.
Check correct operation of the ignitions system and operation of the regulator and operation of the burners individually and
in combination. Burner flames should be clear blue, with no yellow tipping. If the burners show any abnormality check that
the burners are correctly located. If satisfactory performance cannot be obtained, contact Omega service.
Important
Before leaving instruct the owner in the use of the cooker it should be expressly noted that we cannot accept any liability for
direct or indirect damage caused by wrong connection or improper installation. When being repaired, the appliance must
always be disconnected from the mains supply; if required, notify our customer service.
TABLE N°2: GAS BURNER DIMENSION
Burner
Dimension (mm)
Auxiliary
Ø 50
Semi-rapid
Ø 70
Rapid
Ø 95
Wok
Ø 125
Wok 2 ways
Ø 135
SUPPORT LEGS