Loading ...
Loading ...
Loading ...
6
IMPORTANT INFORMATION FOR INSTALLING THE APPLIANCE
The cooker can be installed separately, as a freestanding unit, or between kitchen units or between a kitchen unit and the wall.
This appliance is not connected to devices which exhaust combustion products.
Special attention must be focused on the prescriptions described below regarding room aeration and ventilation.
The dimensions of the appliance are listed below:
LENGTH
DEPTH
HEIGHT
897mm
600mm
900mm (adjustable 870-940)
Room Ventilation
To ensure that the appliance operates correctly, the room where it is installed must be continuously ventilated. The room
volume should not be less than 25m3 and the quantity of air should be based on the regular combustion of gas and on the
ventilation of the room. Natural air will flow through permanent openings in the walls of the room to be ventilated. These
openings will be connected with the outside environment and should have a minimum cross-section defined by current
national standards regarding room ventilation (Fig. 02).
These openings should be built so that they cannot be clogged.
Indirect ventilation is also permitted by taking air from the rooms adjacent to the one to be ventilated.
Fig. 02
Location and Aeration
Gas cooking appliances must always evacuate the combustion products by means of hoods connected to chimneys, flues or
directly outside (Fig. 03). If a hood cannot be installed It is possible to use a fan installed on a window or directly facing
outdoors, to be operated together with the appliance ( Fig. 04), provided that there is strict compliance with the ventilation
regulations.
Fig. 03 Fig. 04
Loading ...
Loading ...
Loading ...