Loading ...
Loading ...
Loading ...
7
Setting and display items Setting details
Vane · Louver · Vent.
(Lossnay)
Use to set the vane angle.
Use to turn ON / OFF the louver.
Select a desired setting from "ON" and "OFF."
Use to set the amount of ventilation.
Select a desired setting from "Off," "Low," and "High."
High power Use to reach the comfortable room temperature quickly.
Units can be operated in the High-power mode for up to 30 minutes.
Timer On/Off timer Use to set the operation On/Off times.
Time can be set in 5-minute increments.
* Clock setting is required.
Auto-Off
timer
Use to set the Auto-Off time.
Time can be set to a value from 30 to 240 in 10-minute increments.
Filter information
Error information Use to check error information when an error occurs.
Error code, error source, refrigerant address, unit model, manufacturing number, contact
information (dealer's phone number) can be displayed.
* The unit model, manufacturing number, and contact information need to be registered in
advance to be displayed.
Weekly timer Use to set the weekly operation On / Off times.
Up to eight operation patterns can be set for each day.
* Clock setting is required.
* Not valid when the On/Off timer is enabled.
Energy
saving
Auto return Use to get the units to operate at the preset temperature after performing energy-save
Time can be set to a value from 30 and 120 in 10-minute increments.
* This function will not be valid when the preset temperature ranges are restricted.
Schedule Set the start/stop times to operate the units in the energy-save mode for each day of the
week, and set the energy-saving rate.
Up to four energy-save operation patterns can be set for each day.
Time can be set in 5-minute increments.
Energy-saving rate can be set to a value from 0% or 50 to 90% in 10% increments.
* Clock setting is required.
Night setback Use to make Night setback settings.
Select "Yes" to enable the setting, and "No" to disable the setting. The temperature range and
the start/stop times can be set.
* Clock setting is required.
Restriction Temp. range Use to restrict the preset temperature range.
Different temperature ranges can be set for different operation modes.
Operation
lock
Use to lock selected functions.
The locked functions cannot be operated.
Maintenance
Auto
descending
panel
Auto descending panel (Optional parts) Up / Down you can do.
Manual
vane angle
Initial setting
Main/Sub
When connecting two remote controllers, one of them needs to be designated as a sub
controller.
Clock
Use to set the current time.
Main display
Use to switch between "Full" and "Basic" modes for the Main display.
The initial setting is "Full."
Contrast
Use to adjust screen contrast.
Main menu list
HWE1309A.qx 3/18/14 12:15 PM Page 7
Loading ...
Loading ...
Loading ...