Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak
Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Care department and have the grill inspected by a cered gas
installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and
piping should be located as shown in the built-in instrucons. A exible metal connector is included to
simplify the installaon of the unit. Connect this connector to the are ng on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass
through a wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to connect the
unit. It must be
connected with rigid pipe, copper tube or an approved exible metal connector which complies
with Z21.4 /
CSA 6.10. The installaon must comply with CAN B149.1 Natural Gas and Propane Installaon
Code in Canada, or to the Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe
must be suciently sized to supply the BTU/h specied on the rang plate, based on the length of the
piping run. If installing a side burner, a separate line must be branched o to the side burner unit and
enter the side burner opening at the specied locaon.
WARNING! Built in units are supplied with a drip pan which holds only a minimal amount of
grease. To prevent grease res, the pan must be cleaned aer each use.
WARNING! Access must be provided to the inside of the enclosure to make gas connecons.
DANGER! Read all instrucons carefully before operang the grill. Failure to follow these
instrucons exactly could result in a re causing serious injury or death. The enre installaon must be
leak tested before operang the grill.