CONNECTING GAS DRYERS
GAS REQUIREMENTS (GAS MODELS ONLY)
To reduce the risk of re,
electric shock, or injury to persons when using this
appliance, follow basic precautions, including
the following:
WARNING:
Gas supply requirements: As shipped from the
factory, this dryer is con gured for use with natural
gas (NG). It can be converted for use with propane
(LP) gas. Gas pressure must not exceed 8 inches
water column (203.2 mm H
2
0) for NG, or 13 inches
water column (330.2 mm H
2
0) for LP.
• A quali ed service or gas company technician must
connect the dryer to the gas service. Failure to follow
these instructions can result in re, explosion, or death.
Isolate the dryer from the gas supply system by
closing its individual manual shuto valve during any
pressure testing of the gas supply. Failure to do so can
result in re, explosion, or death.
Supply line requirements: Your laundry room must
have a rigid gas supply line to your dryer. In the
United States, an individual manual shuto valve
MUST be installed within at least 6 ft. (1.8 m) of the
dryer, in accordance with the National Fuel Gas Code
ANSI Z223.1 or Canadian gas installation code CSA
B149.1. A -inch (0.3 cm) NPT pipe plug must be
installed. Failure to do so can result in re, explosion,
or death.
If using a rigid pipe, the rigid pipe should be ½ inch
(1.2 cm) IPS. If acceptable under local codes and
ordinances and when acceptable to your gas supplier,
-inch (0.95-cm) approved tubing may be used
where lengths are less than 20 ft. (6.1 m). Larger
tubing should be used for lengths in excess of 20 ft.
(6.1 m). Failure to do so can result in re, explosion, or
death.
ELECTRICAL REQUIREMENTS FOR
GAS MODELS ONLY
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord. Failure
to follow this warning can result in re, explosion, or
death.
For personal safety, this dryer must be properly
grounded. Failure to follow this warning can result in
re, explosion, or death.
The power cord of this dryer is equipped with
a 3-prong (grounding) plug which mates with a
standard 3-prong (grounding) wall outlet to minimize
the possibility of electric shock hazard from this
appliance. Failure to follow this warning can result in
re, explosion, or death.
This dryer must be plugged into a 120-VAC, 60-Hz.
grounded outlet protected by a 15-ampere fuse or
circuit breaker. Failure to follow this warning can result
in re, explosion, or death.
Where a standard 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded 3-prong
wall outlet. Failure to follow this warning can result in
re, explosion, or death.
Connect the dryer to the type of gas shown on
the nameplate. Failure to do so can result in re,
explosion, or death.
To prevent contamination of the gas valve, purge the
gas supply of air and sediment before connecting
the gas supply to the dryer. Before tightening the
connection between the gas supply and the dryer,
purge remaining air until the odor of gas is detected.
Failure to do so can result in re, explosion, or death.
DO NOT use an open ame to inspect for gas leaks.
Use a noncorrosive leak detection uid. Failure to do
so can result in re, explosion, or death.
Use only a new AGA- or CSA-certi ed gas supply
line with exible stainless steel connectors. Failure to
do so can result in re, explosion, or death.
Securely tighten all gas connections. Failure to do so
can result in re, explosion, or death.
• Use Te on tape or a pipe-joint compound that is
insoluble in propane (LP) gas on all pipe threads.
Failure to do so can result in re, explosion,
or death.
DO NOT attempt any disassembly of the dryer;
disassembly requires the attention and tools of
an authorized and quali ed service technician or
company. Failure to follow this warning can result in re,
explosion, or death.
3-prong
grounding
plug
3-prong
grounding
type wall
receptacle
Ensure proper
ground exists
before use.
INSTALLATION INSTRUCTIONS