User Manual Omron BP6100 3 Series® Wrist Blood Pressure Monitor

Omron BP6100 3 Series® Wrist Blood Pressure Monitor - Use Manual - Use Guide PDF.
Documents: Go to download!
  • Owner's manual - (English)



User Manual

Know Your Monitor

1 Contents

Monitor, 2 “AAA” alkaline batteries, storage case, instruction manual, quick start guide

2 Monitor

a. Wrist cuff (Wrist circumference 5.3" to 8.5" (13.5 cm to 21.5 cm))

b. Display

c. Battery compartment

d. [Memory] button

e. [Date/Time setting] button

f. [START/STOP] button

3 Display and Symbols

4 Classification of BP (Blood Pressure)

ACC/AHA 2017 Hypertension guidelines define categories of BP in adults as below.

Categories of BP in Adults*

* Individuals with Systolic BP and Diastolic BP in 2 categories should be designated to the higher BP category.

BP indicates blood pressure (based on an average of ≥ 2 careful readings obtained on ≥ 2 occasions).

Source: ACC/AHA 2017 High Blood Pressure Clinical Practice Guideline

Warning

  • NEVER diagnose or treat yourself based on your readings. ALWAYS consult with your physician.

Using Your Monitor

1 Taking a Measurement

Note

  • To stop the measurement, press the [START/STOP] button once to deflate the wrist cuff.

Caution

  • DO NOT use this monitor with other medical electrical (ME) equipment simultaneously. This may result in incorrect operation of the monitor and/or cause an inaccurate reading.
  • Remain still and DO NOT talk while taking a measurement.

1. Press the [START/STOP] button.

All symbols appear on the display before starting the measurement.

2. Remain still and do not move or talk until the entire measurement process is completed.

As the cuff inflates, your monitor automatically determines your ideal inflation level. This monitor detects your blood pressure and pulse rate during inflation.

The “ ” symbol flashes at every heartbeat.

Note

  • When the “ ” symbol is displayed, the wrist cuff is not applied correctly. Press the [START/STOP] button to turn your monitor off, then apply the cuff correctly.

After your monitor has detected your blood pressure and pulse rate, the cuff automatically deflates. Your blood pressure and pulse rate are displayed. If either the systolic or the diastolic reading is high (refer to section 1.3), the “ ” symbol appears.

3. Press the [START/STOP] button to turn your monitor off.

Note

  • Your monitor will automatically turn off after 2 minutes.
  • Wait 2 - 3 minutes between measurements. The wait time allows the arteries to decompress and return to their pre-measurement form. You may need to increase the wait time depending on your individual physiological characteristics.

Using Memory Function

Your monitor automatically stores up to 60 readings.

Note

  • This monitor can be used by multiple users. When you use memory function with other users, track (or manage) your own readings appropriately.

1 Viewing the Readings Stored in Memory

1. Press the button.

The Memory number appears for one second before the pulse rate is displayed. The most recent reading set is numbered “1”.

Note

  • If the reading is high (refer to section 1.3), the “ ” symbol appears.
  • If there are no readings stored in the memory, the screen to the right is displayed.
  • If the memory is full, the monitor will delete the oldest readings.

2. Press the button repeatedly to scroll through the previous readings stored in the memory.

2 Viewing the Average Reading

Your monitor can calculate an average reading based on the latest 2 or 3 readings taken within 10 minutes span.

1. When your monitor is off, press and hold the button for more than 2 seconds.

Note

  • If there are only 2 readings in the memory for that period, the average will be based on these 2 readings.
  • If the average reading is high (refer to section 1.3), the “ ” symbol appears.

Other Settings

1 Deleting All Readings Stored in Memory

1. Press the button, then the “ ” symbol appears.

2. While holding the button down, press and hold the [START/STOP] button for more than 2 seconds.

Note

  • All readings will be deleted. You cannot partially delete the readings stored in the memory

Error Messages and Troubleshooting

In case of any of the below problems occur during measurement, first check that no other electrical device is within 12 inches (30 cm). If the problem persists, please refer to the table below.

appears or the wrist cuff does not inflate.

  • The wrist cuff is not applied correctly.
    • Apply the wrist cuff correctly, then take another measurement. Refer to section 2.4.
  • Air is leaking from the wrist cuff.
    • Contact customer service. Refer to chapter 10.

appears

  • The wrist cuff is overinflated exceeding 300 mmHg.
    • Do not touch the wrist cuff while taking a measurement.

appears

  • You move or talk during a measurement. Vibrations disrupt a measurement.
    • Remain still and do not talk during a measurement.

appears appears appears

  • The pulse rate is not detected correctly.
    • Apply the wrist cuff correctly, then take another measurement. Refer to section 2.4. Remain still and sit correctly during a measurement. If the “ ” symbol continues to appear, we recommend you to consult with your physician.

appears

  • The monitor is malfunctioned.
    • Press the [START/STOP] button again. If “Er” still appears, contact customer service. Refer to chapter 10.

flashes

  • Batteries are low.
    • Replacing all batteries with 2 new alkaline batteries is recommended. Refer to section 2.1.

appears or the monitor is turned off unexpectedly during a measurement

  • Batteries are depleted.
    • Immediately replace all batteries with 2 new alkaline batteries. Refer to section 2.1.

No power. Nothing appears on the display of the monitor.

  • Batteries are completely depleted.
    • Immediately replace all batteries with 2 new alkaline batteries. Refer to section 2.1.
  • Battery polarities are not properly aligned.
    • Check the battery installation for proper placement. Refer to section 2.1.

Readings appear too high or too low.

  • Blood pressure varies constantly. Many factors including stress, time of day, and/or how you apply the wrist cuff, may affect your blood pressure. Review sections 2.3 - 2.5 and chapter 3.

Any other problems occur.

  • Press the [START/STOP] button to turn the monitor off, then press it again to take a measurement. If the problem continues, remove all batteries and wait for 30 seconds. Then re-install batteries. If the problem still persists, contact customer service. Refer to chapter 10

Maintenance

1 Maintenance

To protect your monitor from damage, please follow the directions below:

  • Changes or modifications not approved by the manufacturer will void the user warranty.

Caution

  • DO NOT disassemble or attempt to repair this monitor or other components. This may cause an inaccurate reading.

2 Storage

Keep your monitor in the storage case when not in use.

  • Store your monitor in a clean, safe location.

Do not store your monitor:

  • If your monitor is wet.
  • In locations exposed to extreme temperatures, humidity, direct sunlight, dust or corrosive vapors such as bleach.
  • In locations exposed to vibrations or shocks.

3 Cleaning

  • Do not use any abrasive or volatile cleaners.
  • Use a soft dry cloth or a soft cloth moistened with neutral soap to clean your monitor and wrist cuff, and then wipe them with a dry cloth.
  • Do not wash or immerse your monitor and wrist cuff in water.
  • Do not use gasoline, thinners or similar solvents to clean your monitor and wrist cuff.

4 Disposal

Dispose of your monitor and other components according to applicable local regulations. Unlawful disposal may cause environmental pollution.

Specifications

Note

  • These specifications are subject to change without notice.
  • This monitor is clinically investigated according to the requirements of ISO 81060- 2:2013. In the clinical validation study, K5 was used on 85 subjects for determination of diastolic blood pressure.
  • This monitor has not been validated for use on pregnant patients.
  • IP classification is degrees of protection provided by enclosures in accordance with IEC 60529. This monitor is protected against solid foreign objects of 0.5 inches (12.5 mm) diameter and greater such as a finger, and against oblique falling water drops which may cause issues during a normal operation.



See other models: HJ-321 HEM-907XL BP5250 BP5450 BP7100