User Manual Omron BP629 - 3 Series Wrist Blood Pressure Monitor

Documents for Omron BP629

The following documents are available:
User Manual Photos
BP629 photo

User Manual

For BP629. Series: 3 Series

1. Sit comfortably on a chair with your legs
uncrossed and your feet flat on the floor and
place your elbow on a table in order to relax
before starting blood pressure measurement.
NOTES: The distance from the top of your seat
measuring to the top of the table you
are sitting at, should be 12±2 inches
(30±5 cm). If the distance measured
between the top of your seat and table
do not fall within this parameter, please
correct your seat or table height.
The cuff must be approximately the
same height as your heart. If the cuff is
too high above your heart, your blood
pressure will read artificially low. If the
cuff is too low below your heart, your
blood pressure will be artificially high.
Relax your wrist and hand. Do not
bend your wrist back, clench your fist,
or bend your wrist forward.
2. Press the START/STOP button.
All symbols appear on the display.
The wrist cuff will start to inflate automatically.
As the cuff inflates, the monitor automatically determines your ideal
inflation level. This monitor detects your blood pressure and pulse rate
during inflation. The Heartbeat Symbol ( ) flashes at every heartbeat.
Remain still and do not move until the entire measurement process is
completed.
NOTE: To stop the inflation or measurement, push the START/STOP
button. The monitor will stop inflating, start deflating, and
will turn off.
3. After the monitor has detected your blood
pressure and pulse rate, the cuff automatically
deflates. Your blood pressure and pulse rate
are displayed.
SAFETY INFORMATION
INTENDED USE
This device is a digital monitor intended for use in measuring blood
pressure and pulse rate in adult patient population with wrist
circumference ranging from 5 1/4 inches to 8 1/2 inches (13.5 cm to 21.5
cm). The device detects the appearance of irregular heartbeats during
measurement and gives a warning signal with reading.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury to the user
or patient or damage to the equipment or other property.
INTRODUCTION
Thank you for purchasing the OMRON BP629 Wrist Blood Pressure
Monitor.
The monitor is compact and easy-to-use at home, at work, and during
travel. Perfect for people who frequently monitor their own blood
pressure.
Your new digital blood pressure monitor uses the oscillometric method of
blood pressure measurement. This means the monitor detects your blood’s
movement through your brachial artery and converts the movements into
a digital reading. An oscillometric monitor does not need a stethoscope so
the monitor is simple to use.
Clinical research has proven a direct relationship between blood pressure
in the wrist and blood pressure in the arm. Changes in wrist blood
pressure reflect changes in arm blood pressure because the arteries in the
wrist and the arm are close to each other. Frequently measuring the blood
pressure in your wrist will provide your physician with an accurate
indication of changes in your blood pressure.
Please read this instruction manual thoroughly before using the device.
Please keep for future reference.
For specific information about your own blood pressure, CONSULT
YOUR PHYSICIAN.
3270138-2A
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
• Staple your purchase receipt here
• Register your product on-line at
www.register-omron.com
SAVE THESE INSTRUCTIONS
INSTRUCTION MANUAL
Model BP629
DISPLAY
DISPLAY SYMBOLS
HEARTBEAT SYMBOL ( )
The Heartbeat symbol flashes on the display at every heartbeat during the
measurement.
AVERAGE READING SYMBOL ( )
The Average Reading Symbol is displayed when you press the Memory
button ( ). The most recent average reading appears on the display
screen.
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during
the measurement, the Irregular Heartbeat Symbol will appear on the
display with the readings.
An irregular heartbeat rhythm is
defined as a rhythm that varies by
less than 25% from the average
rhythm or 25% more than the
average rhythm detected while the
monitor is measuring the systolic
and diastolic blood pressure.
If the irregular heartbeat symbol
displays with your readings, we
recommend you consult your
physician. Follow the directions of
your physician.
MOVEMENT ERROR SYMBOL ( )
The Movement Error Symbol ( ) is displayed if you move your body
during the measurement. Please remove the wrist cuff, and wait 2-3
minutes. Reapply the wrist cuff and take another measurement.
WARNING
The monitor is not intended to be a diagnostic device.
WARNING
Consult your physician for specific information about your
blood pressure. Self-diagnosis and treatment using readings
may be dangerous. Follow the instructions of your physician
or licensed healthcare provider.
WARNING
DO NOT adjust medication based on readings from this
blood pressure monitor. Take medication as prescribed by
your physician. Only a physician is qualified to diagnose and
treat High Blood Pressure.
Normal Heartbeat
Irregular Heartbeat
Short Long
Blood
pressure
Pulse
Pulse
Blood
pressure
SETTING THE DATE AND TIME
Set the monitor to the current date and time before taking a measurement
for the first time or after replacing the batteries.
1. TO START THE SETTING
Press and hold the Date/Time Setting
button ( ) until the year flashes on the
display.
2. SETTING THE YEAR
Press the Memory button ( ) to
advance by one year.
Press the Date/Time Setting button ( )
to set the current year.
The month flashes on the display.
NOTES: The year can be set between
2015 and 2040. When the
display reaches 2040, it will
return to 2015.
Press and hold the ( )
button to increase the date
and time values faster.
3. SETTING THE MONTH
Press the Memory button ( ) to
advance by one month.
Press the Date/Time Setting button ( )
to set the current month.
The day flashes on the display.
4. SETTING THE DAY
Press the Memory button ( ) to
advance by one day.
Press the Date/Time Setting button ( )
to set the current day.
The hour flashes on the display.
5. SETTING THE HOUR
The time is set using AM or PM.
Press the Memory button ( ) to
advance by one hour.
Press the Date/Time Setting button ( )
to set the current hour.
The minute flashes on the display.
6. SETTING THE MINUTE
Press the Memory button ( ) to
advance by one minute.
Press the Date/Time Setting button ( )
to set the minute setting.
7. TO TURN THE MONITOR OFF
Press the START/STOP button.
BATTERY REPLACEMENT
Low battery symbol
When the Low battery symbol appears on the display, turn the monitor off
and remove all the batteries. Replace with 2 new alkaline batteries at the
same time.
NOTES: Turn the monitor off before replacing the batteries. If the
batteries are removed while the monitor is still on, the date
and time will be reset to that of the previous use. The readings
are not deleted.
• When the batteries are replaced, you may need to reset the
date and time. If the “-:--” appears on the display, refer to
“Setting the Date and Time”.
• The batteries included with the device may have a shorter life.
CAUTION
Dispose of the device and components according to
applicable local regulations. Unlawful disposal may cause
environmental pollution.
WARNING
If battery fluid should get in your eyes, immediately rinse
with plenty of clean water. Consult a physician immediately.
WARNING
Keep the batteries out of reach of young children.
TAKING A MEASUREMENT
USING THE MEMORY FUNCTION
Every time you complete a measurement, the monitor stores the blood
pressure and pulse rate in the memory. The monitor automatically stores
up to 60 readings (blood pressure and pulse rate). When 60 readings are
stored, the oldest record is deleted to save the most recent readings.
AVERAGING FUNCTION
The monitor calculates the average reading based on up to the 3 most
recent readings taken within 10 minutes.
NOTE: If 2 readings are stored in the memory for the 10 minute period, the
average is based on the 2 readings. If only one reading is stored, this
is displayed as the average.
TO DISPLAY YOUR READINGS
1. Press the Memory button ( ) to display the average reading based on
the 3 most recent readings taken within 10 minutes. The Average
Reading Symbol ( ) appears on the display when the average
reading is shown.
2. Press the Memory button ( ) to display the readings from the most
recent to the oldest.
NOTES: The Memory number appears for a second before the pulse
rate is displayed. The newest set is number “1”.
The date and time are alternately displayed with the
readings.
Press the Memory button ( ) repeatedly to display the
next readings.
Press and hold the Memory button ( ) to display the
readings faster.
3. Press the START/STOP button to turn the monitor off.
BATTERY INSTALLATION
Average reading symbol
Memory symbol
Heartbeat symbol
(Flashes during
measurement)
Blood pressure level
indicator (bar)
Systolic blood pressure
Date/Time display
Diastolic blood pressure
Low battery symbol
Pulse display /
Memory number
Deflation symbol
Irregular heartbeat
symbol
Movement error
symbol
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading, follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for
30 minutes before taking a measurement. Rest for at least 5 minutes
before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during
stressful times.
3. The cuff can be applied to your left or right wrist.
4. Measurements should be taken in a quiet place.
5. Position the unit at heart level throughout the measurement.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your
physician. A single measurement does not provide an accurate
indication of your true blood pressure. You need to take and record
several readings over a period of time. Try to measure your blood
pressure at the same time each day for consistency.
4. Press the START/STOP button to turn the
monitor off.
NOTES: The monitor will automatically turn off after two minutes.
Wait 2-3 minutes between measurements. The wait time
allows the arteries to return to the condition prior to taking
the blood pressure measurement. You may need to increase
the wait time depending on your individual physiological
characteristics.
APPLYING THE WRIST CUFF
Alternating
date/time
display
HEM-6130-Z_A_M07_150731.pdf
CAUTION
Use only 1.5V “AAA” alkaline batteries with this device.
1. Remove the battery cover.
2. Install 2 “AAA” size batteries so the +
(positive) and - (negative) polarities match
the polarities of the battery compartment as
indicated, then replace the battery cover.
NOTES: • Make sure that the battery cover
is securely in position.
Do not touch the battery terminals when you install or
remove the batteries.
ERROR INDICATORS
CARE AND MAINTENANCE
To keep your digital blood pressure monitor in the best condition and
protect the device from damage, follow the directions listed below:
Do not forcefully bend the cuff. Do not fold tightly.
Clean the device with a soft dry cloth.
Do not use any abrasive or volatile cleaners.
Wipe clean on the surface of the cuff with a soft, moistened cloth with a
dilution of neutral detergent.
Do not allow any liquids inside the cuff. If a liquid gets in the cuff, dry
the inside well.
CAUTION
Do not submerge the device or any of the components in water.
CAUTION
Do not subject the monitor to extreme hot or cold temperatures,
humidity or direct sunlight.
CAUTION
Store the device and the components in a clean, safe location.
CAUTION
Do not subject the monitor to strong shocks, such as dropping the
device on the floor.
Remove the batteries if the device will not be used for 3 months or
longer. Always replace all the batteries with new ones at the same time.
Use the device in a manner consistent with the instructions provided
in this manual.
CAUTION
Use only OMRON authorized parts and accessories. Parts and
accessories not approved for use with the device may damage the
device.
CAUTION
Changes or modification not approved by the manufacturer will void
the user warranty. Do not disassemble or attempt to repair the device
or components.
LIMITED WARRANTY
TO DELETE ALL READINGS STORED IN THE MEMORY
You cannot partially delete readings stored in the memory. All readings
will be deleted.
1. Press the Memory button ( ) to turn the monitor on.
2. While holding the Memory button ( ), press the START/STOP
button down for more than 2 seconds until the display appears as it
does in the following illustration.
3. Press the START/STOP button to turn the monitor off.
NOTE: The monitor will automatically turn off after 2 minutes.
Your BP629N Wrist Blood Pressure Monitor, excluding the batteries, is
warranted to be free from defects in materials and workmanship
appearing within 2 years from the date of purchase, when used in
accordance with the instructions provided with the monitor. The above
warranty extends only to the original retail purchaser.
We will, at our option, replace without charge any monitor covered by the
above warranty. Replacement is our only responsibility and your only
remedy under the above warranty.
To obtain warranty service contact Customer Service by calling
1-800-634-4350 for the address of the inspection center and the return
shipping and handling fee.
Enclose the Proof of Purchase. Include a letter, with your name, address,
phone number, and description of the specific problem. Pack the product
carefully to prevent damage in transit. Because of possible loss in transit,
we recommend insuring the product with return receipt requested.
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY
OMRON IN CONNECTION WITH THIS PRODUCT, AND OMRON
HEREBY DISCLAIMS ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT
MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN
DURATION TO THE PERIOD OF THE ABOVE EXPRESS
WARRANTY.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY
OTHER SPECIAL, INCIDENTAL, CONSEQUENTIAL OR
INDIRECT COSTS, EXPENSES OR DAMAGES.
This warranty provides you with specific legal rights, and you may have
other rights which vary from state to state. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation
may not apply to you. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
FOR CUSTOMER SERVICE
Visit our web site at: www.omronhealthcare.com
Call toll free: 1-800-634-4350
FCC STATEMENT
FCC CAUTION
Changes or modifications not expressly approved by the party responsible
for compliance could void the users authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
TROUBLESHOOTING TIPS
PROBLEM
No power.
No display appears
on the monitor.
Readings appear too
high or too low.
CAUSES AND SOLUTIONS
Replace both batteries with new ones at the
same time. Check the battery installation for
proper placement of the battery polarities.
Review the section “Battery Installation”.
Blood pressure varies constantly. Many factors
including stress, time of day, how you wrap the
cuff, where you position your wrist, may affect
your blood pressure.
Review the sections “Before Taking a
Measurement” and “Taking a Measurement”.
SYMBOL CAUSE CORRECTION
Wrist cuff not
applied correctly.
Apply the wrist cuff correctly.
Refer to “Applying the Wrist Cuff”.
Replace the batteries.
Refer to “Battery Installation”.
Do not hold the wrist cuff. Remain
still and do not talk during
measurement. Refer to “Taking a
Measurement”.
Remain still until the measurement
is complete. Refer to “Taking a
Measurement”.
Contact Customer Service.
Apply the wrist cuff correctly.
Refer to “Applying the Wrist Cuff”.
Remain still and do not talk during
measurement. Refer to “Taking a
Measurement”.
Movement during
measurement.
Wrist cuff not
applied correctly or
movement during
measurement.
Arm position
changed during
measurement.
Device error.
Batteries are low.
SPECIFICATIONS
Model:
Display:
Measurement Range:
Accuracy:
Inflation:
Deflation:
Measurement Method:
Rating:
Power Source:
Battery Life:
Operating Temperature
/Humidity:
Storage Temperature
/Humidity/Air Pressure:
Main Unit Weight:
Main Unit Dimensions:
Measurable
Circumference of wrist:
Memory:
Contents:
Applied Part:
Protection Against
Electric Shock:
BP629N HEM-6130-Z
LCD Digital Display
Pressure: 0 to 299 mmHg,
Pulse: 40 to 180 beats/min.
Pressure: ±3mmHg or 2% of reading
Pulse: ±5% of reading
Automatic by electric pump
Automatic rapid deflation
Oscillometric method
DC3V 1.5W
2 “AAA” alkaline batteries 1.5V
Approx. 300 uses with 2 new alkaline
batteries
50ºF to 104ºF (10ºC to 40ºC) /15 to 85% RH
-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH/
700 to 1060 hPa
Approx. 3 5/8oz. (101g)
(not including batteries)
Approx. 3''(w) × 2 3/8''(l) × 7/8''(d)
(78 mm × 60 mm × 21 mm)
(not including the wrist cuff)
Approx. 5 1/4" to 8 1/2" (13.5 to 21.5 cm)
Up to 60 readings
Main Unit, Storage Case, 2 “AAA” Alkaline
Batteries, Instruction Manual, Quick Start
Guide, EMC Information
Internally powered ME equipment
Manufactured for :
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN
Distributed by :
OMRON HEALTHCARE, INC.
1925 West Field Court, Lake Forest, IL 60045 U.S.A.
www.omronhealthcare.com
© 2015 OMRON HEALTHCARE, INC.
Made in Vietnam
Wrist Blood
Pressure Monitor
KNOW YOUR UNIT
Main Unit:
Display
Battery
compartment
Wrist cuff
START/STOP button
Date/Time setting button
Memory button
OPERATING THE DEVICE
Consult your physician for specific information about your blood pressure.
Self-diagnosis and treatment using readings may be dangerous. Follow the
instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on readings from this blood pressure
monitor. Take medication as prescribed by your physician. Only a
physician is qualified to diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device.
Consult your physician before using the device for any of the following
conditions: common arrhythmias such as atrial or ventricular premature
beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age,
pregnancy, pre-eclampsia, renal diseases.
Note that PATIENT motion, trembling, shivering may affect the reading.
If battery fluid should get in your eyes, immediately rinse with plenty of
clean water. Consult a physician immediately.
Keep the batteries out of reach of young children.
Do not use the device on the injured wrist or the wrist under medical
treatment.
Consult your physician before using the device on the arm with an
arterio-venous (A-V) shunt.
Do not use the device with other medical electrical (ME) equipment
simultaneously.
Do not use the device in the area the HF surgical equipment, MRI, or CT
scanner exists, or in the oxygen rich environment.
Consult your physician before using the device for any of the following
conditions:
• If you have had a mastectomy.
• People with severe blood flow problems or blood disorders as cuff
inflation can cause bruising.
Do not take measurements more than necessary. It may cause bruising due
to blood flow interference.
If you have a condition that may compromise circulation, you may get an
inaccurate reading with this device. Consult your physician before using
this device.
Read all of the information in the instruction manual and any other
literature in the box before operating the device.
Do not use this device on infants or persons who cannot express their
intentions.
Operate the device only as intended. Do not use the device for any other
purpose.
Dispose of the device and components according to applicable local
regulations. Unlawful disposal may cause environmental pollution.
Do not use a mobile phone near the device. It may result in an operational
failure.
Use only Omron authorized parts and accessories. Parts and accessories
not approved for use with the device may damage the device.
Use only 1.5V “AAA” alkaline batteries with this device. Do not use other
types of batteries. This may damage the device.
Do not use in a location with moisture, or a location where water may
splash on the device. This may damage the device.
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the
device on the floor.
Do not submerge the device or any of the components in water.
Do not subject the device to extreme hot or cold temperatures, humidity
or direct sunlight.
Store the device and the components in a clean, safe location.
Changes or modification not approved by the manufacturer will void
the user warranty. Do not disassemble or attempt to repair the device
or components.
Do not use the device outside the specified environment. It may cause
an inaccurate reading.
GENERAL PRECAUTION
Read and follow the “Important information regarding Electro Magnetic
Compatibility (EMC)” in the EMC information provided with this device.
Contents: Main Unit, Storage Case, 2 “AAA” Alkaline Batteries,
Instruction Manual, Quick Start Guide, EMC Information
NOTES:These specifications are subject to change without notice.
In the clinical validation study, the 5th phase was used on 85
subjects for determination of diastolic blood pressure.
This device has not been validated for use on pregnant
patients.
2013 ESH/ESC Guidelines for the management of arterial
hypertension
Definitions of hypertension by office and home blood pressure levels
These are from statistical values for blood pressure.
CAUTION
Read all of the information in the instruction manual and any
other literature in the box before operating the device.
CAUTION
This device is intended for use in measuring blood pressure
and pulse rate in the adult population. Do not use this device
on infants or persons who cannot express their intentions.
APPLYING THE CUFF ON THE LEFT WRIST
1. Roll up sleeve. Make sure your sleeve is not
rolled up too tightly on your arm. This may
constrict the flow of blood in your arm.
2. Place the wrist cuff over your wrist. Your palm
should face upward.
3. Position the cuff leaving a clearance of
approximately 1/2 to 1 inch (1 to 2 cm) between
the cuff and the bottom of your palm.
4. Wrap the wrist cuff around your wrist. Do not
apply over clothing.
NOTES: • Wrap the wrist cuff securely around
the wrist for taking accurate
measurements.
Make sure the wrist cuff does not
cover the protruding part of the wrist
bone on the outside of the wrist.
APPLYING THE CUFF ON THE RIGHT WRIST
When taking a measurement using the right wrist
position the cuff as shown in the illustration.
Systolic Blood Pressure
Office Home
≥ 135 mmHg
Diastolic Blood Pressure ≥ 85 mmHg
≥ 140 mmHg
≥ 90 mmHg
WARNING
Consult your physician for specific information about your
blood pressure. Self-diagnosis and treatment using readings
may be dangerous. Follow the instructions of your physician
or licensed healthcare provider.