1. After connecting the gas supply, check the piping and connections for leaks using a
soap and water solution. The presence of bubbles indicates a leak, tighten or
replace connections as appropriate.
Warning: Do not use any naked flame to check for leaks.
2. The operation of the appliance MUST be tested before leaving.
3. Adjust the test point pressure or supply pressure to the value which is appropriate
for the gas type.
4. Turn on the appliance gas controls and light each burner. Check for a well defined
blue flame without any yellow tipping. If any abnormality is evident then check that
the burner cap is located properly and the injector nipple is aligned correctly.
5. Check the minimum burner setting by quickly rotating the gas control knob from
the maximum to the minimum position, the flame must not go out. If adjustment is
required carry out the “minimum burner setting adjustment" procedure described at
page 14.
6. If satisfactory performance cannot be obtained, the installer shall check the installa-
tion and notify the local gas supply authority for a gas supply problem, or if it is an
appliance problem, our Customer Service Centre should be called to obtain the
nearest authorized Delonghi Service Agent.
7. Where the appliance data plate cannot be easily read with the appliance in the
installed position the duplicate data plate must be attached to adjacent surface and
the duplicate Universal LPG conversion label should also be included where a
Universal LPG conversion has been completed.