14 English
Installation
Installation
Ducting requirements
Weather hood type
Recommended Use only for short-run installation
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90°
elbows
Rigid
Metallic
exible*
Rigid
Metallic
exible*
0 80 ft. (24.4 m) 41 ft. (12.4 m) 74 ft. (22.6 m) 33 ft. (10.1 m)
1 68 ft. (20.7 m) 37 ft. (11.2 m) 62 ft. (18.9 m) 29 ft. (8.8 m)
2 57 ft. (17.4 m) 33 ft. (10.1 m) 51 ft. (15.5 m) 25 ft. (7.6 m)
3 47 ft. (14.3 m) 29 ft. (8.8 m) 41 ft. (12.5 m) 21 ft. (6.5 m)
NOTE
* Do not use non-metallic exible duct.
• Use a 4-inch (10.2 cm) diameter rigid aluminum or rigid galvanized steel duct.
• Do not use a smaller duct.
• Ducts larger than 4 inches (10.2 cm) in diameter can cause increased lint accumulation.
Lint accumulation should be cleaned regularly.
• If a exible metal duct must be used, use the type with a stiff sheet metal wall. Do not
use a exible duct with a thin foil wall. Serious blockage can result if the exible metal
duct is bent too sharply.
• Never install any type of exible duct in walls, ceilings, or other concealed spaces.
• Keep the exhaust duct as straight and short as possible.
• Secure joints with duct tape. Do not use screws.
• Plastic exible duct can kink, sag, be punctured, reduce airow, extend drying times, and
affect dryer operation.
• Exhaust systems longer than recommended can extend drying times, affect machine
operation, and may collect lint.
• The exhaust duct should end with an exhaust hood with a swing-out damper to prevent
back drafts and the entry of wildlife. Never use an exhaust hood with a magnetic damper.