Troubleshooting Guide
Symptoms Check Solution
It is hard to
remove
the smell
or
the unit has a
smell
Is the pre-fi lter too dirty?
Refer to “Pre-filter” in “Cleaning” when cleaning
the pre-fi lter.
(P.E-34)
Is the fi lter dirty?
Or is it time to replace the fi lter?
Refer to “Replacing the Filter Assembly / Deodor-
izing Filter” when replacing the fi lter.
Depending on the location or usage, the replace-
ment interval may be shorter.
(P.E-37)
Is the humidifying fi lter dirty?
Or is it time to replace the humidifying fi lter?
Refer to “When the Filter Cleaning Indicator
Comes On” in “Cleaning” when cleaning the hu-
midifying fi lter.
(P.E-28 - E-31)
The airfl ow rate
switched in the
middle of operation
Is it set in “Auto” airfl ow rate, or “Pollen” or “Eco
Saving Operation” quick cycles?
Switch airfl ow rate and quick cycle.
(P.E-21, E-22)
Are the rear panel, filters, and humidifying filter
correctly set?
Set them correctly.
Following Conditions are Normal
Sounds and Vibrations
Symptoms Cause (This is normal)
When using humidify or skin moisturize
modes, the purifi er sometimes makes whir-
ring and gargling sounds
It is the sound of the unit pumping water from the water tank for a
few seconds every few minutes.
The unit makes rattling sounds when it is
being moved
It is the sound of the metal ball inside the “Vibration Sensor”.
The flap makes whirring, rattling, and rumbling
noises when it is opened, closed, or in swing mode
It is the sound of the motor that moves the fl ap.
The unit vibrates when it is on “Max” airfl ow rate.
It is because of the rotation of the fan.
The airflow rate frequently switches in the
middle of humidify mode
and the sound is distracting
It is because the airflow rate is controlled automatically. When
the humidity changes, the airfl ow rate may switch to “High”.
If it becomes a distraction, switch to your preferred airfl ow rate.
(P.E-21)
The humidifying performance will decrease when it is switched
to a weaker airfl ow rate.
Heat and Smells
Symptoms Cause (This is normal)
The air coming out of the air outlet smells
The unit’s parts have a smell when it is fi rst used.
Or the deodorizing performance of the deodorizing fi lter has de-
creased.
Clean the deodorizing fi lter.
(P.E-34)
Or there are odors clinging to the humidifying fi lter. Clean the hu-
midifying fi lter.
(P.E-28 - E-31)
The Touch Operation Panel is warm
The unit’s interior is lined with control circuits.
This causes the unit to become warm.
EP-A9000_EN.indd 41EP-A9000_EN.indd 41 11/18/2014 11:02:19 AM11/18/2014 11:02:19 AM