INSTALLATION INSTRUCTIONS
DIP SWITCH CONFIGURATIONS BY PANEL CONTROL
1. Turn off the appliance.
2. Press and hold the increase and decrease buttons at the same time for 3 seconds to activate the dip
switch confi guration by panel control.
3. See the table below for dip switch confi gurations and functions by panel control.
4. The display will show two numbers. The high left number is for dip switches, the low right number is for
functions.
5. Press the increase button to set the dip switches. Press the decrease button to set the functions.
6. Press and hold the increase and decrease buttons at the same time for 3 seconds to confi rm choices.
The appliance will return to regular functioning after 30 seconds with no input.
Note: The LED display window will show “00” when fi rst entering setting mode. Set switches in sequence
one at a time.
Note: To activate front desk control function, set dip switch SW7 to “DOWN(OFF)” and then set the panel
control to “A0”.
Number High (left) Low (right) Remarks
/ 0 1 - by panel control 0 - by dip switches
S1 1 1 - electric heat only 0 - electric and pump heat Heat pump
model only
S2 2 1 - °F display 0 - °C display
S3*S9 3 3 - use control panel or some types of wall thermostat
2 - use some types of wall thermostat
1 - use PTAC other wall thermostat
0 - use control panel
Consult with
sales agent or
manufacturer for
details
S4*S5 4 4 - 62°F ~ 86°F (17°C ~ 30°C)
3 - 61°F ~ 86°F (16°C ~ 30°C)
2 - 65°F ~ 78°F (18°C ~ 26°C)
1 - 63°F ~ 80°F (17°C ~ 27°C)
0 - 68°F ~ 75°F (20°C ~ 24°C)
S6 6 1 - continuous fan for heating 0 - fan cycle for heating Not available
for “use PTAC
other wall
thermostat”
S7 7 1 - continuous fan for cooling 0 - fan cycle for cooling
S8 8 1 - low temperature protection
enable
0 - low temperature protection
disable
Optional
SW7 A 1 - front desk control enable 0 - front desk control disable Optional
Sw11 B 1 - load delay for 3 seconds 0 - normal Optional