A. 3/8"  exible gas connector
B. 1/2" NPT adapter
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve
GAS SUPPLY LINE
Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the washer/dryer. See illustration below.
1/2" IPS pipe is recommended.
Must include shut-off valve:
In the U.S.A.:
An individual manual shut-off valve must be installed within
six (6) ft. (1.8 m) of the washer/dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1. The location should
be easy to reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) ft. (1.8 m)
of the washer/dryer. The location should be easy to reach
for opening and closing.
This washer/dryer is equipped with its own permanent,
exible gas connector, design-certi ed by CSA International,
for connecting the washer/dryer to the gas supply line.
DRYER GAS CONNECTION
Option 1
Rigid gas supply line:
Connect your washer/dryer to the rigid gas supply line using
the 1/2" NPT adapter between the gas supply line and the
exible gas connector on the washer/dryer.
Option 2
Approved aluminum or copper tubing:
3/8" approved aluminum or copper tubing is acceptable for
lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.
If you are using natural gas, do not use copper tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter  tting.
If your washer/dryer has been converted to use propane gas, 3/8"
propane compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of propane
gas must be used. Do not use TEFLON
®†
tape.
A
B
E
D
C
Flexible gas connector
®
TEFLON is a registered trademark of Chemours.
GAS SUPPLY CONNECTION REQUIREMENTS
Use the 1/2" NPT adapter between the gas supply line
and the  exible gas connector on the washer/dryer.
Use only pipe-joint compound. Do not use TEFLON
®
tape.
BURNER INPUT REQUIREMENTS
Elevations up to 10,000 ft (3,048 meters):
The design of this washer/dryer is certi ed by CSA
International for use at altitudes up to 10,000 ft (3,048 m)
above sea level at the Btu rating indicated on the model/serial
number plate. Burner input adjustments are not required when
the washer/dryer is operated up to this elevation.
Elevations above 10,000 ft (3,048 meters):
When installed above 10,000 ft. (3,048 m), a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft. (305 m) increase in elevation.
Gas supply pressure testing
The washer/dryer must be disconnected from the gas supply
piping system during pressure testing at pressures greater
than 1/2 psi.
1. Pull foam packing ring out of washer
Open the washer lid. The latch under the dryer will keep
the lid open. Pull the foam packing ring and drain hose
out of the washer.
NOTE: Keep the foam ring and use it when transporting
your washer/dryer. This packing material is used to keep
the washer tub stable during transport.
Remove Foam Packing
(24" [61 cm] models)