Electrical Requirements,
240V Electric Models – Canada
It is your responsibility:
n To contact a qualied electrical installer.
n To be sure that the electrical connection is adequate and in
conformance with Canadian Electrical Code, C22.1 – latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
n To supply the required 4-wire, single-phase, 120/240 volt,
60 Hz, AC only electrical supply on a separate 30 amp
circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
n This dryer is equipped with a UL Listed
and/or CSA International Certied Power
Cord intended to be plugged into a standard
14-30R wall receptacle. The cord is 5 ft.
(1.52 m) long. Be sure wall receptacle is
within reach of dryer’s nal location.
4-wire receptacle
(14-30R)
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference service numbers located
in “Assistance or Service” section of your Use and Care Guide.
Electrical Requirements,
120V Electric Models – U.S.A.
and Canada (24" [61 cm]
Models Only)
n It is recommended that a separate circuit breaker
serving only this appliance be provided.
n 120V models are equipped with a power supply
cord having a 3 prong grounding plug intended
to be plugged into a 20 amp 5-20R wall receptacle.
n To minimize possible shock hazard, the cord
must be plugged into a mating, 3 prong,
grounding-type outlet, grounded in accordance
with local codes and ordinances. If a mating outlet is not
available, it is the personal responsibility and obligation
of the customer to have the properly grounded outlet installed
by a qualied electrician.
n If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
n Check with a qualied electrician if you are not sure the
washer/dryer is properly grounded.
n Do not have a fuse in the neutral or ground circuit.
n 120 volt, 60 Hz, AC only, 20 amp fused electrical
supply is required. A time-delay fuse or circuit breaker
is recommended.
It is your responsibility:
n To contact a qualied electrical installer.
n To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70 – latest edition or the Canadian Electrical Code, C22.1 –
latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269 or Canadian Standards Association, 178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
n Do not use an extension cord.
5-20R
receptacle