4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
Drill with 1¼" (3 cm), 3/8" (9.5 mm), 7/64" (2.75 mm) and
1/8" (3 mm) drill bits
Pilot hole drill bits (determined by chimney support
attachment method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts needed
Home power supply cable
1/2" (12.7 mm) UL listed or CSA approved strain reliefs (2)
UL listed wire connectors (3)
For vented installations, you will also need:
Wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also
need:
Recirculating Kit for non-vented (recirculating) installations
only. See “Assistance or Service” section to order.
6" (15.2 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and LED light installed
Filter - installed in hood canopy
Levelling screws (2)
Nuts (2)
4.2 x 8 mm screws (60)
5 x 45 mm screws (4)
Mounting template
Upper vent covers (2)
Lower vent covers (2)
Vent transition with back draft damper installed
3.5 x 9.5 mm mounting screws (2)
Plastic vent clips (4)
Upper horizontal support bracket
Horizontal support
Vertical supports (8)
3.5 x 6.5 mm screws (4)
2.9 x 3 mm screws (2)
T10® Torx®† adapter
T20® Torx® adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualied technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specied on the model/serial/rating plate. The model/serial rating
plate is located behind the left lter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 100 lbs (45.4 kg).
This range hood is recommended for use with cooktops with a
maximum total rating of 78,000 BTUs or less.
The range hood is factory set for venting through the roof.
For non-vented (recirculating) installation, see “Non-vented
(recirculating) Installations” in “Assemble and Install Range
Hood” section. Recirculation Kit Part Number W10692909 is
available from your dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
*Vented installations only
**Non-vented (recirculating) installations only
(31.0 cm)
12
¹⁄₄
"
(33.5 cm)
13³⁄₁₆"
36" (91.2 cm)
min.
*32¹⁄₂"
(82.6 cm)
(118.0 cm)
max.
*46¹⁄₂"
(82.6 cm)
**32¹⁄₂"
min.
**52⁹⁄₁₆"
(133.5 cm
)
max.
27" (68.6 cm)
†®TORX, T10 and T20 are registered trademarks of Acument Intellectual Properties, LLC.