 49-7769
Installation Instructions
INSTALLATION INSTRUCTIONS
3ODQIRUSURSHUHOHFWULFDOVXSSO\GUDLQVDQG
ductwork locations.
,QVWDOOZDOOSOHQXP
,QVWDOOWKHJULOOH
%XLOGDQGLQVWDOOSODWIRUP
3ODFHXQLWRQWKHSODWIRUPDQGVOLGHWKHH[WHULRUVLGH
of the unit into the plenum until it is fully seated.
INSTALLATION SEQUENCE
6. Make drain connections per instructions included
in this manual.
7. Connect unit to the ductwork.
8. Connect the thermostat.
&RQQHFWWKHHOHFWULFDOSRZHU
,QVWDOODLUUHWXUQJULOOHRUDFFHVVFRYHU
5HYLHZWKHLQVWDOODWLRQFKHFNOLVW
&KHFNRSHUDWLRQRIWKHXQLW
Build and Install the Zoneline Base Platform
1. Construct a 23-
»´PLQ[
»´PLQVTXDUHSODWIRUPZLWKOHJVWRUDLVHWKHSODWIRUPDPLQLPXPRI´
127(7KHSODWIRUPPXVWKDYHDORDGEHDULQJFDSDFLW\RIOEVPLQLPXP
2. 'UDLQFRQQHFWLRQVFDQEHPDGHWRWKHULJKWOHIWRUUHDURIWKHXQLW7KHXQLWGLPHQVLRQVDUH
/8´[
/8´
,IWKHSODWIRUPLVODUJHUWKDQWKHXQLWGUDLQKROHVPD\QHHGWREHFXWWKURXJKWKHSODWIRUP'UDLQFXWRXWV
connections need to be determined by the installer for the given installation situation.
3. Place the platform in the utility closet with the following clearance between it and the interior surface of the
walls/door/panel:
´PLQIURPIURQWRIWKHXQLW±8QLWWREHLQVWDOOHGWKURXJK)5217RIFDVH
´PLQIURPWZRVLGHVRIWKHXQLW
4. Align the platform with the opening of the wall plenum and secure to the floor using appropriate brackets
and bolts.
23-
»´ min.
Recommended platform height:
´PLQIRUGUDLQDFFHVV3ODWIRUP
VXUIDFHVKRXOGEH´EHORZZDOO
plenum opening. See Plenum
,QVWDOODWLRQ,QVWUXFWLRQVIRUGHWDLOV
127(6SHFLILFFXWRXWVL]HIRUGUDLQ
connections (if required) needs to be
determined by the installer for the given
installation situation.
23-
»´ min.
Condensate Disposal System
7KH&RQGHQVDWH'LVSRVDO6\VWHPLQFUHDVHVHQHUJ\HIILFLHQF\XWLOL]LQJDIDFWRU\LQVWDOOHGIDQWKDWVOLQJVWKH
condensate onto the hot outdoor coil.
:KHQKLJKRXWGRRUKXPLGLW\SUHYHQWVWKHVOLQJHUIURPGLVSRVLQJRIDOOFRQGHQVDWHWKHH[FHVVFRQGHQVDWH
RYHUIORZVLQWRWKHFRQGHQVDWHGUDLQSDQDQGRXWRIWKH´LQWHUQDOGUDLQFRQQHFWLRQV
NOTE: If the Condensate Disposal System fails to remove all of the condensate from the unit, any
excess condensate will overflow from a spillway in the rear of the unit directly into the wall plenum,
and drain outside the building. This is your indication that the chassis or drain requires servicing.
Install the Wall Plenum
,QVWDOOWKHZDOOSOHQXP5HIHUWRLQVWUXFWLRQVLQFOXGHG
LQWKHZDOOSOHQXPNLW5$9:3RU5$9:37IRU
proper installation procedures.
Install the Grille
,QVWDOOWKHJULOOH5HIHUWRLQVWUXFWLRQVLQFOXGHG
in the grille kit RAVAL2 for proper installation
procedures.
INSTALLATION INSTRUCTIONS