Carbamazepine 1400 ± 20% 200 ng/L 99.20%
Phenytoin 200 ± 20% 30 ng/L 99.3% / 98.6.%
Naproxen 140 ± 20% 20 ng/L 93.3%
Bisphenol A 2000 ± 20% 300 ng/L 98.9%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.89 lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to
71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/
incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only
trace levels, these compounds can affect the public acceptance/perception of drinking water quality.
For installation, operation, and maintenance instructions please
refer to the use & care guide.
It is important that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised. Property damage can occur if all
instructions are not followed.
The disposable cartridge must be changed at least every 6
months.
Use replacement filter P8RFWB2L, part #EDR1RXD1/
EDR1RXD1B. 2015 suggested retail price of $49.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
The filter monitor system measures the amount of water that
passes through the filter and alerts you when it is time to replace
the filter.
Refer to the “Using the Controls” or “Water Filtration System”
section (in the User Instructions or User Guide) to learn how to
check the water filter status.
After changing the water filter, flush the water system. See
“Water and Ice Dispensers” or “Water Dispenser” in the User
Instructions or User Guide.
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and
local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts. EPA Est. No.
082047-TWN-001
Refer to the “Warranty” section (in the User Instructions or User
Guide) for the Manufacturers limited warranty, name and
telephone number.
Application Guidelines/Water Supply Parameters
Water Supply Potable City or Well
Water Pressure 30 psi - 120 psi (207 kPa -
827 kPa)
Water Temperature 33°F - 100°F (0.6°C - 37.8°C)
Service Flow Rate 0.50 GPM (2.27 L/min.) @
60 psi (413.7 kPa)
Your water filtration system will withstand up to 120 pounds per
square inch (psi) water pressure. If your water supply is higher
than 80 psi, install a pressure reducing valve before installing
the water filtration system.
*Class I particle size: >0.5 to 1 um
†Based on the use of Cryptosporidium parvum oocysts
††Fibers greater than 10 um in length
®
NSF is a registered trademark of NSF International.