6
Figure 3
Important note:
This appliance shall not
be used as a space heater, especially if installed in marine
craft or caravans.
CLEARANCES:
Installation clearances and protection of combustible surfaces shall comply with the
current local regulations e.g. AS/NZS5601 - Gas Installations code.
490
50
270
300
510
52
(1)
490
50
270
300
510
52
(1)
(1): 52 mm from top of countertop.
(2): at least 50 mm between the back side of the cut-out and the back
of the countertop.
Figure 4
(3): at least 200 mm from the periphery of the nearest burner to any
vertical combustible surface. If the distance from the periphery of
the nearest burner to any vertical combustible surface, or vertical
combustible surface with toughened glass or sheet metal, is less
than 200 mm, the surface shall be protected (in accordance with
AS/NZS5601) to a height of not less than 150 mm above the hob
for the full dimension (width or depth) of the cooking surface area.
(2) (3)
(2) (3)