MINIMUM BURNER SETTING ADJUSTMENT
Check whether the flame spreads to all burner ports when the burner is lit with
the gas tap set to the minimum position. If some ports do not light, increase the
minimum gas rate setting.
Check whether the burner remains lit even when the gas tap is turned quickly
from the maximum to the minimum position. If the burner does not remain lit,
increase the minimum gas rate setting.
The procedure for adjusting the minimum gas rate setting is described below.
using a screwdriver turn screw "A" until the flame setting is correct (fig. 13).
Model DE302GB: Normally for ULPG fully tighten the adjustment screw.
Model DE30WGB: Normally for ULPG fully tighten the adjustment screw,
then turn the screw 3/8 anti-clockwise.
LUBRICATING THE GAS TAP
If a gas tap is difficult to turn, disassemble it, clean it carefully with petrol and spread
a little high-temperature-resistant grease on it.
These operations must be performed by an Authorized person/Service agent.
Note: Ser
vicing of this appliance is only to be carried out by Authorised Person.