CONVERSION PROCEDURE (to convert to Natural gas or to
ULPG)
REPLACING THE INJECTORS
The conversion procedure must be carried out only by an authorised person.
This appliance is suitable for use with Natural gas or Universal LPG (check the “gas
type” sticker attached to the appliance). The nominal gas consumption and injector
size details are provided in table at page 11.
To replace the injectors proceed as follows:
Remove pan supports and burners from the cooktop.
Using a spanner, remove the injector J (figs.11, 12) and replace it with one
according to the gas type (see tables - page 11).
Affix to the appliance the warning label stating that the cooktop has been convert-
ed for use with Natural gas/ULPG (supplied with the Natural gas/ULPG conversion
kit). A second Natural gas/ULPG conversion label should also be affixed to an
adjacent surface along with the duplicate data plate.
IMPORTANT
If the cooktop is suitable for use with Natural gas and must be converted for
use with Universal LPG, before connecting to gas main remove the appliance
gas regulator and replace with test point adaptor (see fig. 8, 9).
If the cooktop is suitable for use with Universal LPG and must be converted for
use with Natural gas, before connecting to the gas main remove the appliance
test point adaptor and replace with gas regulator (see figs. 8, 9).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with
conversion kit)
The burners are designed so that regulation of primary air is not required.