Maytag WCD3090JW laundry

User Manual - Page 19

For WCD3090JW.

PDF File Manual, 64 pages, Download pdf file

Loading ...
Loading ...
Loading ...
19
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
4-Wire Power Supply Cord Strain Relief:
IMPORTANT: Use the strain relief supplied with the dryer.
Power Supply Cord Connection
4-Wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use
of 3-wire connections.
4-wire receptacle
(NEMA-type 14-30R)
4 prong plug
Spade terminals with
upturned ends
Ring terminals
Attach power supply cord to strain relief
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. Do not further tighten strain relief screws at
this point.
Power supply cord 4-wire receptacle
(NEMA-Type 14-30R):
Go to “4-Wire Power Supply Cord
Connection.”
Power supply cord 3-wire receptacle
(NEMA-Type 10-30R):
Go to “3-Wire Power Supply Cord
Connection.”
If your outlet looks like this:
Connect neutral wire (white or center) (C) of power supply cord
under center terminal block screw (B). Tighten screw.
1. Connect neutral wire
B
C
D
Connect ground wire (F) (green or bare) of power supply
cord under green external ground conductor screw (A).
Tighten screw.
2. Connect ground wire
F
A