Rangehoods
Rangehoods and overhead
exhaust fans must
be installed according to
manufacturers’ instructions
.
Rangehoods should be installed not lower than 650mm
above the cooktop.
Ventilation
A cooker should not be installed in any room which has a volume less than 5.6 cu. m.
(200 cu. ft.). If the room is between 5.6 Cu. m. (200 cu. ft.) and 11.2 cu. m. (400 Cu. ft.)
in volume, provision must be made for permanent ventilation. Above 11.2 cu. m. (400 cu.
ft.) volume, no special provision needs to be made unless other gas burning appliances
are installed in the same room. Ventilation must always be provided if a cooker is
installed in a cellar or a basement. The manufacturer does not accept damage caused
directly or indirectly by failure to comply with the above.
6
50mm
Allow a 5mm gap
on each side
1.
Location of gas inlet
Bottom rear of upright cooker:
60 mm from RH side
400 mm from base without legs installed
2. Electrical connection
Connection is by means of flexible cord and plug . Check the data plate - models
with consumption greater than 2400W require a 15amp connection.
3. Overall dimensions of upright cooker
Depth over cabinet 600 mm
Height over hob 760/750 mm (CHECK MODEL) IT965 Models = 760mm
Height over splashback 810/820mm (check model)
534 series width 530 mm
664 series width 598 mm
865 series width 798 mm
965 series width 898 mm
765 series width 698 mm
On models with removable legs add up to 150 mm.
The adjustable legs are screwed into the base of the cabinet and the height adjustment
is achieved by rotating the lower portion of the legs clockwise or anti-clockwise as
appropriate.
REFER TO PAGE 6 FOR INSTALLATION OF ANTI TILT BRACKET
Glem Gas Australasia Pty Ltd and their appointed agents decline any responsibilities in
the case of installation not according to these instructions.