02 INSTALLING YOUR DRYER
CONNECTING THE INLET HOSE
Method 1
The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old
hoses.
1. If space permits, attach the brass female end of the “Y”
connector to the cold water faucet.
2. Turn the cold water faucet o .
3. Attach the straight end of long hose to the “Y’ connector.
4. Using pliers, tighten the coupling with an additional two-
thirds turn.
Do not overtighten, as this may damage the coupling.
5. Attach the angled end of long hoses to fi ll the valve at the
bottom of the dryer’s rear frame. Screw on the coupling by
hand until it is seated on the fi ll valve connector.
6. Using the pliers, tighten the coupling with an additional two-
thirds turn.
Do not overtighten, as this may damage the coupling.
7. Check that the water faucets are on.
8. Check for leaks around the “Y” connector, faucets and
hoses.
Duct Exhaust
Frame
(back)
Water Hose
Y-Connector
Water Hose