Exhaust air connection
You can use the exhaust air set
which can be obtained from
customer service or your local
dealer (WTZ1130).
Also any products which are
commercially available can be used
for the exhaust air duct:
flexible tubes,
galvanised sheet metal ducts or
tubes,
connection, transfer and
by-pass adapters for use in
flat duct or tubular ducting
systems,
wall boxes for ventilation into the
open air or into an air shaft,
adapters for rectangular ducts,
rectangular ducts or plastic
tubesone-way flap.
The Bosch dryers are intended to
be vented outdoors. To prevent
build-up of moisture and
accumulation of lint indoors, as well
as to maintain maximum drying
efficiency, it is recommended that
the dryer is vented outdoors.
Position the exhaust air duct
so that there is no counter-
pressure (e.g. from wind) on
the exhaust outlet.
Rear panel connection
The dryer is delivered with an
exhaust air outlet on the rear of the
appliance. The exhaust air vent on
the left-hand side panel is closed
and covered.
Select the most suitable exhaust air
outlet.
Left-hand side panel connection
1. Remove the cover from the
side panel.
2. Remove the bayonet ring from
the rear panel and attach it to
the side panel vent.
3. Close off the rear panel vent
with the cover.
CAUTION
All materials must be
heat-resistant up to 80 °C and
humidity-resistant.
CAUTION
1. To reduce the risk of fire, this
dryer MUST BE EXHAUSTED
OUTDOORS.
2. To reduce the risk of fire, do
not use the ductwork longer
than recommended.
3. DO NOT use a plastic or
non-metal duct with this
dryer.
4. DO NOT use a duct smaller
than 4 inches in diameter.
5. DO NOT use exhaust hoods
with magnetic latches.
6. DO NOT exhaust the dryer
into: a chimney, wall, ceiling,
concealed space of a
building, furnace cold air
duct, attic, crawl space, or
any other ductwork used for
venting.
7. DO NOT install a flexible
duct in an enclosed wall,
ceiling or floor.
8. DO NOT crush or kink the
duct.
9. Do clean and inspect the
exhaust system on a regular
basis; at least once a year.
10. The exhaust duct must
terminate in a manner to
prevent back drafts or entry
of birds or other wildlife.