HEATING MODE
In this mode, the air conditioner heats the room. To activate heating mode, press the Mode
Control button until the RED indicator comes on. When the heating mode is set, the rear fan will
start first, followed by the compressor then the air output fan into the room.
Note: The compressor will start in approximately 3-5 minutes and it will take approximately 3-5
additional minutes for heat to blow from the front air output vent.
The temperature setting range of this air conditioner is from 61°F to 77°F. To set the temperature,
press the + or - buttons. Once the set temperature is achieved, the compressor and the fan will
stop.
Note: This unit uses a heat pump for heating and heating mode will not work when temperature is
below 45F.
In heating mode, cold air is exhausted from the outdoor exhaust port and the exhaust hose must
be connected to exhaust the cold air produced by the unit.
If outside temperature is lower than room temperature, the air intake hose should be removed
and the included cover placed onto the air intake fixture. The unit will take in air from the room air
filter.
Note: When the compressor is running, the sound difference between each fan speed is not very
noticeable.
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner.
The time (hours) delay can be set, enabled and disabled. The timer is adjustable between 1-24
hours.
SETTING SWITCH OFF TIMER
With the air conditioner operating in any function mode, press the Timer Control button. Then set
the desired
time delay OFF hours by pressing the + or - buttons. When the delay time set has
elapsed, the air conditioner switches off.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the Timer Control button. Then set the desired time delay ON
hours by pressing the + or - buttons. When the delay time set has elapsed, the air conditioner
switches on.
AUTO RESTART
In
the event of a power outage, the air conditioner restarts at the previously set function mode and
settings when
power is restored.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are
normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder
than they actually are.
The compressor may make a pulsating or high-pitched sound.
Water running from the evaporator to the water tank may make a splashing sound.
Refrigerant flowing may make a gurgling sound.
Fan sound may come from front and back air vents.
COMPRESSOR LOCK OUT
This portable air conditioner is optimized to operate in an ambient temperature of 64°F – 90°F. The
compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly.