20
Troubleshooting
When Error occurs, the front use button (ICE-WATER-ICE & WATER) of the door lights alternately to
the left and right. Restart after action.
When the button is lit alternately to the left and right, open the door and press the bottom setting
button of the control buttons, Error display will appear.
Display
Error type
Causes
Action
Release
Operation
Er01
Evaporator
temperature
error
When the Evaporator
temperature is 0 ° C or more
after 30 minutes passed
during the ice making
Check refrigerant
leakage
Check sensor and
attachment
abnormality
Resupply
power after
resolving
cooling
problem
Stop ice making
Er03
Evaporator
temperature
error
When the Evaporator
temperature is over -5 ° C
after 30 minutes passed
Check refrigerant
leakage
Check sensor and
attachment
abnormality
Resupply
power after
resolving
cooling
problem
Keep on ice
making
Er06
Temperature
sensor error
Displayed when temperature
sensor is open or shorted.
Check sensor and
attachment
abnormality
Start operation
after sensor
part repair
Stop ice making
Er13
High
pressure
switch error
Condenser dust, fan motor
failure, cold cycle
abnormality, etc.
Remove dust,
Check Fan motor
Check for
abnormal cold
cycle
Automatic
return after
action
Stop
compressor.
Stop motor after
operating 10
seconds.
Er14
High
pressure
switch error
Occurs when High pressure
switch is OPEN 3 times or
more
Contact service
representative
Start operation
after action
Stop
compressor.
Stop motor after
operating 10
seconds.
Er15
Water
supply error
When water level is not
detected by the water level
sensor due to no water
supply for 120 seconds.
Water supply
pressure check
Water level
sensor check
Start operation
after action
Stop ice making
Er16
Water level
sensor
defect
At the start of ice making,
when the upper and lower
limits are not detected by the
water level sensor for 60
seconds
Replacement of
Water Level
Sensor
Start operation
after action
Stop ice making
Er25
Motor
restraint
Occurs when Evaporator inlet
/ outlet temperature is -18
or less for 10 minutes.
Poor water supply, Agitator
restraint,
Ice jams due to scale
Unlock ice jams
Check water
supply line
Check motor
restraint fault
Start operation
after action.
Machine stops
after 3
repetitions
Stop ice making
Loading ...