Disinfection
wash
Dilute 10 L of warm water and 400 mL of 5.25% sodium hypochlorite solution (bleach).
( Dilution ratio may vary depending on the solution manufacturer, please refer to the solution
manual).
If this is the minimum amount to be used, use more washing solution.
To ensure safety and maximum effect, please use the washing solution immediately after
dilution.
Disinfection
procedure -
initial
1) Shut off the water supply by closing the valve of the water supply line and make sure
that the power switch is turned to “OFF” position and the power plug is disconnected from
the outlet, and then remove the front panel and the upper panel.
2) Pour the disinfectant solution over the water inlet until the evaporator assembly and the
water tank are full.(Until the disinfecting solution overflows to the drain box)
3) Open the top cover and disassemble the ice reservoir lid.
4) Disassemble packing, bush, etc. inside the lid.
5) Turn the Agitator to the left to disassemble it.
6) Remove the Ice Base Plate.
7) Disinfect the inside of the reservoir and the removed parts for 10 minutes and wipe
them.
8) Remove Spout, clean for 10 minutes and wipe.
9) Please thoroughly rinse all parts with clean water. ( If there is residual washing
solution, it will cause corrosion.)
10) Assemble all parts in the correct position.
11) Connect the power plug to the outlet, turn the power switch to “ON”, turn the ICE
MAKING-OFF-WASH switch to “ICE MAKING” and keep the operation until the
disinfectant solution is exhausted and the ice production stops.
12) Switch the ICE MAKING-OFF-WASH switch to the "WASH" position and let the
remaining water drain out for 5 minutes.
13) Turn the power switch to “OFF” and disconnect the power plug from the outlet.
Disinfection
procedure -
final
1) Mix the disinfection solution in a new bowl.
2) Check that the water valve is closed, the power switch is turned off and the power plug
is disconnected from the outlet, and then remove the front panel and the upper panel.
3) Pour the disinfectant solution over the water inlet until the evaporator assembly and the
water tank are full.
(Until the disinfecting solution overflows to the drain box)
4) Leave the ice maker for 10 minutes before operating the ice maker.
5) Connect the power plug to the outlet, turn on the power switch, and turn the ICE
MAKING-OFF-WASH switch to 'ICE MAKING' until the disinfectant solution is exhausted
and the ice stops generating.
6) Switch the ICE MAKING-OFF-WASH switch to 'WASH' and drain the remaining water
for 5 minutes.
7) Switch the ICE MAKING-OFF-WASH switch to "ICE MAKING" and open the valve of
the ice-maker water supply line so that water can be supplied to the water tank.
8) When the geared motor starts to operate, switch the ICE MAKING-OFF-WASH switch
to the 'OFF' position.
9) Switch the ICE MAKING-OFF-WASH switch to 'WASH' and discharge the remaining
water for 5 minutes.
10) Turn the ICE MAKING-OFF-WASH switch to 'ICE MAKING' position to generate ice for
30 minutes, then turn off the power switch.
11) Pour warm water into the ice reservoir to dissolve the ice and drain it. Use a neutral
detergent to wash the reservoir. After washing, rinse thoroughly with clean water.