Condition/Problem Things to Check Solution
Reset Machine Unplug unit from electrical outlet for 3 minutes. Reconnect to
outlet.
Check magnet position
(requires shroud removal)
Magnet should be in place on pulley.
Check Speed Sensor
(requires shroud removal)
Speed sensor should be aligned with magnet and connected to
data cable. Realign sensor if necessary. Replace if there is any
damage to the sensor or the connecting wire.
Unit rocks/does not sit
level
Check leveler adjustment Adjust levelers until bike is level.
Check surface under unit Adjustmentmaynotbeabletocompensateforextremelyun-
even surfaces. Move bike to level area.
Pedalsloose/unitdifcult
to pedal
Check pedal to crank arm
connection
Pedal should be tightened securely to crank. Insure connection
is not cross-threaded.
Clicking sound when
pedaling
Check pedal to crank arm
connection
Remove pedals and reattach.
Seat post movement Check locking pin Be sure adjustment pin is locked into one of the seat post
adjustment holes.
Check adjustment knob Be sure knob is securely tightened.