Renogy RBT50LFP48S-US 48V 50Ah Smart Lithium Iron Phosphate Battery

User Manual - Page 17

For RBT50LFP48S-US.

PDF File Manual, 20 pages, Read Online | Download pdf file

RBT50LFP48S-US photo
Loading ...
Loading ...
Loading ...
ConditionBattery Operation Status
Triggering
Recovery
Charge
Over-current
Primary
Protection
Secondary
Protection
Triggering
Recovery
Warning
Triggering
Recovery
Triggering
Recovery
Discharge
Over-current
Short Circuit
Primary
Protection
Secondary
Protection
Triggering
Recovery
Warning
Triggering
Recovery
Protection
Triggering
Recovery
Battery Cell Balancing
The battery employs bypass circuit to maintain the balance between each battery cell group.
Each battery cell group is connected with a bypass resistor and a switch in parallel. During the
charging process, if the highest-voltage battery cell group reaches the set balancing starting
voltage and the voltage difference between the highest-voltage and the lowest-voltage battery
cell group exceeds the set voltage difference, the switch connected to the highest-voltage
battery cell group will be closed to shunt the charge current around the highest-voltage battery
cell group through the bypass resistor until the voltage difference drops below the set value. To
avoid excessive energy loss, the battery cell balancing is only performed during the charging
process.
Charge Current≥51A
Charge Current≤40A
Charge Current≥55A (Delay 15s)
Charge Current≤40A (Delay 1min) /
Discharge Current≥1A
Charge Current≤40A (Delay 1min) /
Discharge Current≥1A
Charge Current≥120A
Discharge Current≥51A
Discharge Current≤45A
Discharge Current≥55A (Delay 15s)
Discharge Current≤40A (Delay 1min) /
Charge Current≥1A
Discharge Current≤40A (Delay 1min) /
Charge Current≥1A
Discharge Current≥120A
Discharge Current≥400A (Delay 300μs)
Remove Short Circuits / Charge Current≥1A