Step 4-1: Installing In-hood 600 CFM Blowers Duct Connection Detail: 6 Round
Recommended Duct Size: 6 | Minimum Duct Size: 6
Figure A:
Attach Blower
Unscrew blower plate and
set to top or rear discharge.
Screw blower to plate with
included hardware
Figure B:
Connect Plate Internally
Re-install all mounting
screws inside of liner.
Figure C:
Connect Plate Externally
Re-install all mounting
screws outside of liner.
Figure D:
Connect Power Supply
Connect molex connector
from control box to blower.
Step 4-2: Installing In-hood 1200 CFM Blowers Duct Connection Detail: 10 Round
Recommended Duct Size: 10 | Minimum Duct Size: 8
INSTALLATION INSTRUCTIONS
Figure A:
Attach Blower Plate
Unscrew blower plate and
set to top or rear discharge.
Figure B:
Connect Inner Plate
Screw inner plate with air
divider onto base plate.
Figure C:
Connect Blowers
Install dual 600 CFM
blowers onto hood with
included hardware.
Connect molex connectors
to blowers.
Figure D:
Install Blowers in Hood
Screw each blower to the
plate within the liner with
hardware provided.
9